White Link - L.B. White Premier CS350DF 2.0 Owner's Manual And Instructions

Ductable heater
Hide thumbs Also See for Premier CS350DF 2.0:
Table of Contents

Advertisement

Available languages

Available languages

10
Premier Ductable Heater
the heater on and off within a temperature
differential of ±3°F (±1.5 °C).
14. Take time to understand how to operate and
maintain the heater by using this Owner's
Manual. Make sure you know how to shut off the
gas supply to the building and also to the
individual heater. Contact your fuel gas supplier if
you have any questions.
15. Any defects found in performing any of the
service or maintenance procedures must be
eliminated and defective parts replaced
immediately. The heater must be retested by
properly qualified service personnel before
placing the heater back into use.
Gas Supply Sizing
The vaporization of propane is affected by several
factors: the surface area of the container, the liquid
level of propane, temperature surrounding the
container, and the relative humidity. All of these
factors are specific to a site. Therefore, a degree of
experience and judgement is required to select the
proper propane supply.
Although experience is the best guide, the follow-
ing recommendations can be used as a starting
point. The table is based on experience in northern
climates where cold weather and high humidity are
prevalent in the winter. If more or less favorable
conditions prevail at a specific site, adjustments can
be made on the basis of experience.
Recommended Gas Supply
TANK SIZE
500 gall. / 1892 litre
1000 gall. / 3784 litre
If more than one gas supply container is used per
heater, the containers must be manifolded together
to allow vapor withdrawal simultaneously from
multiple containers. Manifold system shall be in
accordance with NFPA 58 or CSA B149.1.
Owner's Manual • Premier 350DF 2.0
HEATERS / TANK
1
2
Connecting Hose to
Heater
1. Thread swivel onto connector at gas inlet of heater.
See Fig. 1. Tighten securely.
2. The hose may be coiled up and hung on the hose
hanger, with the regulator stored within the regulator
storage bracket.
FIG. 1
SWIVEL
(Sold separately, 500-133225)
The Premier 350DF 2.0 is factory configured to be L.B.
White LINK Ready.
For more information on the L.B. White LINK system,
contact your local L.B. White Dealer. You may also call
the L.B. White Company, LLC at 1-800-345-7200.