A
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.

Parallel Operation

The Champion model 93001i-DF-UK is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion parallel kit (optional
equipment) is required for parallel operation. Model 755001i-WL-
UK is the recommended model for this unit. For a list of compatible
models or to order a parallel kit, please call customer service at
+44(0)-1942-715-407 or visit www.championpowerequipment.
co.uk
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator's
manual.
Do Not use both 230v AC and 12v DC at the same time
otherwise you could damage the generator or equipment
resulting in voiding your warranty.

12v DC Regulated Automotive Style Outlet

The 12V DC outlet(s) can be used with supplied accessories and
other commercially available 12V DC automotive style plugs.
Confirm the input voltage range of your item is at least 12-24V DC.
When charging a device, do not place on the exhaust side of
the generator. Extreme heat caused by exhaust can damage
the device and cause a potential fire hazard. Prolonged
exposure to engine exhaust can cause serious injury or death.
Battery Charging
1. Before connecting the battery charging cable to a battery
that is installed in a vehicle, disconnect the vehicle battery
ground cable from the negative (–) battery terminal.
CAUTION
CAUTION
WARNING
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
Important: The 12V DC outlet is ONLY to be used with supplied
accessories and other commercially available 12V DC automotive
style plugs. Be sure all electric devices including the lines and
plug connections are in good condition before connection to the
generator.
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Parallel Operation
The Champion model 93001i-DF-UK is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion parallel kit (optional
equipment) is required for parallel operation. Model 500740-WL-
EU is the recommended model for this unit. For a list of compatible
models or to order a parallel kit, please call customer service at
+44(0)-1942-715-407 or visit www.championpowerequipment.
co.uk
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator's
manual.

Stopping the Engine

Petrol
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the fuel vent lever to the "OFF" position.