Champion 93001i-DF-UK Operator's Manual page 19

3000w dual fuel inverter generator
Table of Contents

Advertisement

93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR
area provides notification that the generator shut off due to an
accumulating CO hazard. The red LED light will blink for at least
five (5) minutes after an engine shut off event.
AUTOMATIC SHUTOFF
AUTOMATIC SHUTOFF
SEE ACTION LABEL
SEE ACTION LABEL
AUTOMATISCHE ABSCHALTUNG
AUTOMATISCHE ABSCHALTUNG
SIEHE AKTIONSKENNZEICHNUNG
SIEHE AKTIONSKENNZEICHNUNG
AUTOMATISCHE ABSCHALTUNG
AUTOMATISCHE ABSCHALTUNG
VOIR ETIQUETTE D'ACTION
VOIR ETIQUETTE D'ACTION
Move the generator far away to an open, outdoor area and point
the exhaust away from people and buildings. Once relocated
to a safe area, the generator can be restarted, and the proper
electrical connections made. Introduce fresh air and ventilate the
location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
This blinking LED light does not indicate CO ShieldR is
working,CO ShieldR is on and active at all times when the
generator is running.LED light will not blink (10) times if the
generator was restarted within 1 minute after it was turned
off. This LED blinking indication does not occur if the generator
is shut down from a high CO event.
If CO ShieldR system experiences a fault and no longer provides
protection, the generator will shutoff automatically and the yellow
LED light will blink for at least five (5) minutes to notify you of the
fault
SERVICE
SERVICE
Call our Technical Support Team at +44(0)-1942-715-407 for
repair. The generator can be restarted, but will continue to shutoff.
NOTICE
CO ShieldR will detect an accumulation of carbon monoxide
(CO) from other fuel burning sources such as engine powered
equipment, and(or) heaters used in the area of its operation. If
another generator is used and the exhaust stream is pointed
in the direction of the CO ShieldR equipped generator, the CO
ShieldR will initiate a shutoff due to rising carbon monoxide
(CO) levels. This is not a fault, It simply means high levels
of Poisonous carbon monoxide (CO) has been detected.You
must take action to move and direct the generator exhaust or
heaters stream to better disperse carbon monoxide (CO) far
away from people or buildings as possible..
Tampering with the CO Shield
hazardous condition and will void your warranty.
Removing the CO ShieldR module is not allowed and will result
in the generator not being able to start, by doing so this will
void any warranty.