Champion 93001i-DF-UK Operator's Manual

Champion 93001i-DF-UK Operator's Manual

3000w dual fuel inverter generator

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #93001i-DF-UK
3000W DUAL FUEL INvERTER GENERATOR
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.co.uk
Original Instructions
+44(0)-1942-715-407
or visit www.championpowerequipment.co.uk
SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
This product meets the requirements of the PGMA (Portable Generator Manufacturers' Association) standard ANSI/PGMA G300-2018 (Safety and Performance of
Portable Generators).
Covered by one or more of the following U.S. Patent Numbers: 10,641,187, 10,862,414 and other U.S. and foreign patents pending.
REV 20230329

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 93001i-DF-UK and is the answer not in the manual?

Questions and answers

Summary of Contents for Champion 93001i-DF-UK

  • Page 1 OPERATOR'S MANUAL MODEL #93001i-DF-UK 3000W DUAL FUEL INvERTER GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.co.uk Original Instructions +44(0)-1942-715-407 or visit www.championpowerequipment.co.uk SAvE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect CARBON MONOXIDE K ILLS your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR TAbLE OF CONTENTS Cleaning the Spark Arrestor ........Adjusting the Governor ........... Introduction ...........
  • Page 4: Introduction

    93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product. CPE designs, builds, and supports all of our products to strict specifications and guidelines.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. DANGER Rotating parts can entangle hands, feet, hair, clothing and/or Generator exhaust contains carbon monoxide, a colourless, accessories. Traumatic amputation or severe laceration can odorless, poisonous gas.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR WARNING CAUTION Spark from removed spark plug wire can result in fire or Exceeding the generator’s running capacity can damage the electrical shock. generator and/or electrical devices connected to it.
  • Page 7: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Fuel Safety When adding or removing petrol: DO NOT light or smoke cigarettes. DANGER Turn the generator off and let cool for at least two minutes before removing the fuel cap. Always loosen the cap slowly to relieve PETROL, PETROL VAPORS AND PROPANE (LPG) ARE pressure in the tank.
  • Page 8: Safety And Dataplate Labels

    Oktanzahl 85. Maximal 10% Ethanol. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 9: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 10: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 11: Quickstart Label Symbols

    2. Add fuel. Check petrol level. When adding petrol, use a This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 12: Controls And Features

    CONTROLS AND FEATURES 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1.
  • Page 13: Control Panel

    CONTROLS AND FEATURES 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Control Panel 1. Circuit Breakers (Push Reset) – Protects the generator RECEPTACLES against electrical overloads. 240V AC, 16A 2. Economy Mode Button – Enables/disables automatic idle May be used to supply electrical power for control.
  • Page 14: Parts Included

    CONTROLS AND FEATURES 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Parts Included Accessories LPG Hose with Regulator .......... 12V DC Battery Charging Cable ........12V DC USB Adapter ..........16A Plug- Dual 13A Sockets Adpater ......
  • Page 15: Assembly

    ASSEMbLY 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR ASSEMbLY 2. Loosen the four cover screws and remove the maintenance cover. Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.
  • Page 16: Add Fuel: Petrol

    ASSEMbLY 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR than ¼ in. (6.4 mm) is recommended. Petrol can be forced NOTICE  out of the tank as a result of expansion if overfilled, and can affect the stable running condition of the generator.
  • Page 17: Add Fuel: Propane (Lpg)

    ASSEMbLY 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR NOTICE  The generator engine works well with 10% or less ethanol blended petrol. When using ethanol-petrol blends there are some issues worth noting: – Ethanol-petrol blends can absorb more water than petrol alone.
  • Page 18: Grounding

    2mm safe margin; white to be printed shown in 50% process magenta This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
  • Page 19 OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR area provides notification that the generator shut off due to an NOTICE  accumulating CO hazard. The red LED light will blink for at least five (5) minutes after an engine shut off event.
  • Page 20: Generator Location

    OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Generator Location WARNING WARNING Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the NEVER operate the generator inside any building, garage, generator at all times.
  • Page 21: Starting The Engine: Propane (Lpg)

    OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR NOTICE  For petrol starting in standard ambient temperature >59°F (15°C): Keep EZ Start dial in “CHOKE” position for three pulls of the recoil cord. If generator does not start after three pulls, rotate the EZ Start dial to the “RUN”...
  • Page 22 OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR 5. Slowly pull the starter cord 3-5 times to prime the engine. 5. When starting the engine, pull the recoil cord slowly until resistance is felt, release cord back and use one strong rapid pull to start, this avoids any kickback or damage to the recoil assembly.
  • Page 23: Connecting Electrical Loads

    OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Connecting Electrical Loads 4. If the generator power output is cut off due to an overload condition indicated by the AC overload blinking light, lower Let the engine stabilize and warm up for a few minutes after the load by unplugging one or more items, then press the starting.
  • Page 24: Parallel Operation

    It will not give the battery a boost of power. The vehicle or the generator may The Champion model 93001i-DF-UK is parallel ready and can be be damaged. Charge only vented wet lead acid batteries.
  • Page 25: Moving The Generator

    OPERATION 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR CAUTION  When running on propane the EZ dial will be disabled for safety, the only way to stop generator is to close of the cylinder tap. 4. Turn the EZ Start dial counterclockwise to the “STOP”...
  • Page 26: Operation At High Altitude

    MAINTENANCE 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR MAINTENANCE Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
  • Page 27: Changing The Engine Oil

    MAINTENANCE 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Cleaning and Adjusting the Spark Plug 1. Recommended every 50 hours use or annually. Remove the Changing the Engine Oil maintenance cover. Recommended every 100 hours or annually Change oil when the engine is warm.
  • Page 28: Cleaning The Air Filter

    MAINTENANCE 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Cleaning the Air Filter 1. Recommended every 100 hours use or 1 month. Allow the engine to cool completely before touching or servicing the spark arrestor. 2. Locate the air filter plastic cover and remove by pinching the clips together and pulling the cover off.
  • Page 29: Storage

    STORAGE 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Contact our Technical Support Team at +44(0)-1942-715-407 to NOTICE  locate the nearest CPE certified service dealer for your generator or engine maintenance needs. The following storage instructions are only necessary if using petrol.
  • Page 30: Long Term Storage (More Than 1 Year)

    STORAGE 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR 11. Re-install the spark plug and spark plug wire. 1. Be sure the EZ Start dial is in the “STOP” position. 12. Re-install the maintenance cover. 2. Add petrol to the generator according to Add Fuel.
  • Page 31: Specifications

    SPECIFICATIONS 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ........93001i-DF-UK Capacity ........
  • Page 32 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Problem Cause Solution Engine governor defective. Contact the help line. Dirty fuel valve. Clean the fuel valve. Engine hunts or falters. Carburetor is dirty and running lean. Contact the help line. Choke in wrong position.
  • Page 33 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure A Parts Diagram...
  • Page 34 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure A Part List Part Number Description Qty. Part Number Description Qty. 100010946-0001 Screw M4 x 10 Bolt 100098636-0001 Cover, Fuel Switch Handle Fuel Tube, L=295mm 100715786-0002 100769795 Bolt M4 x 16 Clamp 2, Ø11.5 x 10...
  • Page 35 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure E Parts Diagram...
  • Page 36 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure E Part List Part Number Description Qty. Fuel Strainer 100009020 Rubber Pad 100072727-0001 100731679 Fuel Tank, 4.5 L 100072726-0005 Fuel Tank Cap Flange Bolt M5 x 10 100010831-0001 Fixed Clamp 100714562-0001 100728784...
  • Page 37 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure F Parts Diagram...
  • Page 38 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure F Part List Part Number Description Qty. Parallel Port Cover, 100765674-0002 Square, Black Parallel Port Cover, 100765674-0001 Square, Red 100019997 Receptacle 100120180 Cover, Circuit Breaker 16Amp Circuit Breaker, 100019758-0002 Push Button O-Ring...
  • Page 39 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure G Parts Diagram...
  • Page 40 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure G Part List Part Number Description Qty. Vibration Mount, Support 100072715-0001 Housing Assembly, 100088546 Bottom, Black 100050562 Threaded Clamp 100072711 Housing, Bottom, Black Step Nut M6 100072994 Nut M6 100011452-0010 100072712 Foot, Bottom Housing...
  • Page 41 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure b Engine Parts Diagram...
  • Page 42 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure b Engine Part List Part Number Description Qty. Part Number Description Qty. Big Flange Bolt M6 x 12 Dowel Pin Ø8 x 12 100011570-0008 100010549 100097810 Spark Plug(E6RTC) 42 100158680 Washer Ø14.2 x 0.5 x Ø21...
  • Page 43 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure C Parts Diagram...
  • Page 44 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure C Part List Part Number Description Qty. Rocker Arm Assembly 100760595 100158127 Shaft, Rocker Arm Valve Collet 100075055 Oil Drip Pan 100758247 100075056 Valve Spring Seat, 148F Spring Valve 100159357 Cylinder Head...
  • Page 45 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure D Parts Diagram...
  • Page 46 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Figure D Part List Part Number Description Qty. Gasket, Insulator 100158108 Insulator, Carburetor 100158118 100158117 Gasket, Carburetor 100733457 Carburetor Stepper Motor 100061512 Fuel Bowl O-Ring 100131960 100005759 Main Jet Standard (63) 100005736 Main Jet Standard (61)
  • Page 47: Wiring Diagram

    93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Wiring Diagram 16A , C.B Brown Brown AC socket Stepper motor Yellow Parallel Terminal Blue Orange Blue Blue Pink Yellow/Green Yellow/Green Inverter Module Yellow/Green Main Brown RESET winding BUTTON White White Inverter Unit winding...
  • Page 48: Troubleshooting

    TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
  • Page 49 TROUbLESHOOTING 93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR Problem Cause Solution Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak. Make sure there are no objects creating obstructions within 5 feet of the generator.
  • Page 50: Warranty

    Please register within ten (10) beyond the manufacturer’s control. days from date of purchase. – Problems caused by parts that are not original Champion Repair/Replacement Warranty Power Equipment parts. When applicable, this warranty does not apply to products used CPE warrants to the original purchaser that the mechanical and for prime power in place of a utility or city power.

Table of Contents