Grounding; Operation; Co Shield ® - Carbon Monoxide (Co) Detection And Auto-Shutoff System - Champion 93001i-DF-UK Operator's Manual

3000w dual fuel inverter generator
Table of Contents

Advertisement

93001i-DF-UK - 3000W DUAL FUEL INvERTER GENERATOR
A
Use approved LPG cylinders equipped with an OPD (overfilling
prevention device) valve. Always keep the cylinder in a vertical
position with the valve on top and installed at ground level
on a flat surface. Cylinders must not be installed near any
heat source and should not be exposed to sun, rain, and dust.
When transporting and storing, turn off the cylinder valve and
generator LPG valve, and disconnect the cylinder. Plug the
outlet, usually by a plastic protective cap, if one is available.
Keep cylinders away from heat and ventilated when in a
vehicle.
A
If there is a strong smell of LPG: Close valve on the cylinder.
Check all connections for leaks by wetting the fittings with a
solution of soap and water. Bubbles which appear or bubbles
which grow indicate that a leak exists. Do not smoke or light a
cigarette, or check for leaks using a match, open flame source
or lighter. Contact a qualified technician to inspect and repair
an LPG system if a leak is found, before using the generator.

Grounding

Your generator must be properly connected to an appropriate
ground to help prevent electric shock.
A
Failure to properly ground the generator can result in electric
shock.
A ground terminal connected to the panel of the generator has
been provided (see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge
(12 AWG minimum) copper wire between the generator ground
terminal and a copper rod driven into the ground. We strongly
recommend that you consult with a qualified electrician to ensure
compliance with local electrical codes.
Neutral Floating*(This generator)
– Neutral circuit IS NOT electrically connected to the frame/
ground of the generator.
– The generator (stator winding) is isolated from the frame and
from the AC receptacle ground pin.
– Electrical devices that require a grounded receptacle pin
connection will not function if the receptacle ground pin is not
functional.
CAUTION
WARNING
WARNING
Neutral Bonded to Frame*
– Neutral circuit IS electrically connected to the frame/ground of
the generator.
– The generator system ground connects lower frame cross-
member below the alternator. The system ground is connected
to the AC neutral wire.
* See your Specifications section for specified type of grounding.

OPERATION

CO Shield
- Carbon Monoxide (CO) Detection
®
and Auto-shutoff System
CO Shield
technology monitors the accumulation of carbon
®
monoxide (CO), a poisonous gas produced by engine exhaust when
the generator is running. If CO Shield
levels of CO gas, it automatically shuts off the engine.
CO SHIELD
IS NOT A SUbSTITUTE FOR AN INDOOR CARbON
®
MONOXIDE ALARM OR FOR INDOOR OPERATION.
DO NOT allow engine exhaust fumes to enter a confined area
through windows, doors, vents or other openings.
Generators must ALWAYS be used outdoors, far away from
occupied buildings with engine exhaust pointed away from people
and buildings.
If misused and operated in an unapproved and unsafe location
that results in the accumulation of poisonous CO gas inside
an enclosed or partially enclosed space, for example a house,
garage or a garage with the door partially open, CO Shield
automatically shut off the generator and then will illuminate a
blinking red LED light. Read the action label for next steps.
1106-BY-L-A
In the event of an engine shut off, when you approach the
generator to investigate, a blinking red LED light in the CO Shield
18
OPERATION
detects unsafe elevated
®
®
A
ACTION LABEL
AUTOMATIC SHUTOFF – YOU MUST:
Using a generator indoors CAN KILL YOU IN
Move generator to an open,
MINUTES. Generator exhaust contains carbon
outdoor area. Point exhaust away.
monoxide. This is a poison you cannot see or
Don't run generators in enclosed
smell.
areas (eg sheds, garages, houses or any out
NEVER use inside a home or garage or any out
buildings).
building, EVEN IF doors and windows are
Move to fresh air and get medical help if sick,
open.ONLY use OUTSIDE and far away from
dizzy or weak.
windows, doors, and vents.
APN
1106-BY-L
Rev
A
Size
~203 x 75 mm
Artwork Notes
2mm safe margin; white to be printed shown in 50%
process magenta
This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for
outside parties without the explicit consent of Champion Power Equipment.
will
DANGER
Colors
K
2945 123 482 152
P
®
Revision Changes

Advertisement