Functional Description - Makita PC5000C Instruction Manual

Concrete planer
Hide thumbs Also See for PC5000C:
Table of Contents

Advertisement

Available languages

Available languages

Symbols
The followings show the symbols used for tool.
volts
amperes
hertz
alternating current
rated speed
no load speed
Class II Construction
revolutions or reciprocation per minute
FUNCTIONAL
DESCRIPTION
CAUTION:
Always be sure that the tool is switched off and
unplugged before adjusting or checking function
on the tool.
Switch action
B
► 1. Lock lever 2. Switch trigger
CAUTION:
Before plugging in the tool, always check to see
that the switch trigger actuates properly and
returns to the "OFF" position when released.
Switch can be locked in "ON" position for ease
of operator comfort during extended use. Apply
caution when locking tool in "ON" position and
maintain firm grasp on tool.
2
A
1
To prevent the switch trigger from accidentally pulled, a
lock lever is provided. To start the tool, push in the lock
lever (B) and then pull the switch trigger (A). Release
the switch trigger to stop. For continuous operation,
push in the lock lever (B), pull the switch trigger (A) and
then push in the lock lever (B) further. To stop the tool
from the locked position, pull the switch trigger (A) fully,
then release it.
Electronic function
Constant speed control
Possible to get fine finish, because the rotating
speed is kept constantly even under the loaded
condition.
Additionally, when the load on the tool exceeds
admissible levels, power to the motor is reduced
to protect the motor from overheating. When the
load returns to admissible levels, the tool will
operate as normal.
Soft start feature
Soft start because of suppressed starting shock.
Indication lamp
► 1. Indication lamp
The indication lamp lights up green when the tool is
plugged. If the indication lamp does not light up, the
mains cord or the controller may be defective. The indi-
cation lamp is lit but the tool does not start even if the
tool is switched on, the carbon brushes may be worn
out, or the controller, the motor or the ON/OFF switch
may be defective.
Unintentional restart proof
Even locking lever keeping the switch trigger depressed
(Lock-on position) does not allow the tool to restart even
when the tool is plugged.
At this time, the indication lamp flickers red and shows
the unintentional restart proof device is on function.
To cancel the unintentional restart proof, pull the switch
trigger fully, then release it.
5 ENGLISH
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc5001c

Table of Contents