Feature Description - Dräger Quaestor 4000 Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

7
Blind plug
8
High pressure outlet
9
Medium pressure inlet
10
High pressure inlet
Dräger Quaestor 8000 (viewed from front)
14
13
12
11
22
21
20
19
18
11
Connector for breathing adapter
12
Gel face
13
Measuring point (in the eye)
14
Adapter for mask/helmet combinations
15
Connector for lung demand valve/medium pres-
sure outlet
16
Medium pressure inlet
17
High pressure inlet
18
High pressure outlet
19
Bracket for pressure gauge or Bodyguard
20
Connector for filling the chemical protective suit
21
Status LED
22
Self-contained breathing apparatus bracket
(optional, only the lower section is shown)
Viewed from rear
23
25
Instructions for use
|
Dräger Quaestor 4000/6000/8000
23
Lever for locking and removing the test head
24
USB port for connection to a PC
25
Power supply
NOTICE
To ensure the functional safety of the test unit, only
Dräger accessories may be connected to the inputs and
outputs.
3.1.1 Explanation of symbols
Symbol
15
16
17

3.2 Feature description

The leak-tightness and functional integrity of various
breathing safety products can be tested with the test
units. The Dräger Quaestor 4000/6000 is a semi-
automatic test unit, the Dräger Quaestor 8000 is fully
automatic.
An artificial lung enables breathing simulation during
breathing tests on the Dräger Quaestor 6000 and 8000
only. Tests requiring an artificial lung are marked with
"Q6/8 only".
The test units are operated via a PC. The software
included with the device guides the user through the
test steps and logs the test results. The test results can
be saved and printed. Test date monitoring ensures that
the inspection intervals are observed.
The following accessories are included with the Dräger
Quaestor 8000:
– External microphone
The microphone registers the signal of the acoustic
warning whistle when inspecting a self-contained
open-circuit breathing apparatus or closed-circuit
breathing apparatus.
– Bracket for pressure gauge or Bodyguard
The bracket is available as an option for the Dräger
Quaestor 4000/6000.
The following accessories are available as options:
24
Explanation
Chemical protective suit connector
(Quaestor 8000 only)
Caution! High pressure connection
Inlet
Outlet
Risk of crushing!
|
Description
15

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Quaestor 6000Quaestor 8000

Table of Contents