17
. BATTERY/CHARGING SYSTEM
VOLTAGE INSPECTION
Remove the battery cover .
Measure the battery voltage using a
commercially available digital multimeter.
Voltage (20ºC/68ºC):
Fully charged: 13-13.2 V
Insufficient charged: below 12.3 V
BATTERY CHARGING
Remove the battery
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Turn the power ON/OFF at the battery
charger, not at the battery terminals.
Charging current time:
Standard: 1 .2A/5-10h
Quick: 5A/1h
Quick charging should only be done in an
emergency; slow charging is preferred.
For battery charging, do not exceed the
charging current and time specified on the
battery. Using excessive current or extending
the charging time may damage the battery.