• FQXSPNM4060I: IP address of default gateway of network interface [arg1] is modified from [arg2]
to [arg3] by user [arg4].
This message is for the use case where a user modifies the default gateway IP address of a Management
Controller.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0288
User Action:
Information only; no action is required.
• FQXSPOS4000I: OS Watchdog response [arg1] by [arg2] .
This message is for the use case where an OS Watchdog has been enabled or disabled by a user.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0012
User Action:
Information only; no action is required.
• FQXSPOS4001I: Watchdog [arg1] Screen Capture Occurred .
This message is for the use case where an operating system error has occurred and the screen was
captured.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0028
User Action:
Complete the following steps until the problem is solved:
1. If there was no operating-system error:
2. Reconfigure the watchdog timer to a higher value.
3. Make sure that the BMC Ethernet-over-USB interface is enabled.
4. Reinstall the RNDIS or cdc_ether device driver for the operating system.
5. Disable the watchdog.
6. If there was an operating-system error, check the integrity of the installed operating system.
• FQXSPOS4002I: Watchdog [arg1] Failed to Capture Screen.
This message is for the use case where an operating system error has occurred and the screen capture
failed.
Severity: Error