Lenovo 7D96 Manual page 155

Table of Contents

Advertisement

c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, please ensure steps
a, b, and c above are also performed for that adapter before proceeding.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFIO0013I: The device found at Bus [arg1] Device [arg2] Function [arg3] could not be
configured due to resource constraints. The Vendor ID for the device is [arg4] and the Device ID is
[arg5]. The physical slot number is [arg6].
Severity: Warning
User Action:
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded,
reseat adapter and any attached cables.
2. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.(NOTE: It may be necessary to disable unused option ROMs from UEFI F1
setup, OneCLI utility, or using adapter manufacturer utilities so that adapter firmware can be
updated.)
3. Move the adapter to a different slot. If a slot is not available or error recurs, replace the adapter.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFIO0014J: A bad option ROM checksum was detected for the device found at Bus [arg1]
Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The
physical slot number is [arg6].
Severity: Error
User Action:
Complete the following steps:
1. If thisPCIe device and/or any attached cables were recently installed, moved, serviced or upgraded.
Reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check Lenovo support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.
Note: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFIO0015I: IFM: System reset performed to reset adapters.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFIO0016M: IFM: Reset loop avoided - Multiple resets not allowed.
.
151
Chapter 3
UEFI events