1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0034M logs will provide the correct location for PMEMs.
4. Move all PMEMs of error message FQXSFMA0034M logs to the correct location.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
• FQXSFMA0034M: DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory interleave set
should be moved to DIMM slot [arg3] in sequence.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. Details included in this error message will provide the correct location for that PMEM.
4. Move the PMEM to the correct location.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
• FQXSFMA0035M: Intel Optane PMEM interleave set should have [arg1] PMEMs, but [arg2] PMEMs
are missing.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0036M logs will provide the details which PMEMs are
missing.
4. Find all missing PMEMs of error message FQXSFMA0036M logs and install them in the correct
location.
5. If an error occurs, follow steps 1 and 4 to get details on new error message.
6. If the problem persists, collect Service Data logs.
7. Contact Lenovo Support.
• FQXSFMA0036M: DIMM [arg1] (UID: [arg2]) of Intel Optane PMEM persistent memory interleave set
is missing.
Severity: Warning
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. This error message will provide the UID of the missing PMEM,
4. Use Lenovo Service Client or contact Lenovo Support to parse log to get correct location for PMEM
Find the missing PMEM and install it in the correct location.
.