Lenovo 7D96 Manual page 62

Table of Contents

Advertisement

SNMP Trap ID: 43
CIM Prefix: PLAT CIM ID: 0508
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSPMA2007I: Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName] has recovered.
This message is for the use case when an implementation has detected a Memory Scrub failure recovery.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0137
User Action:
Information only; no action is required
• FQXSPMA2010I: [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no
longer Throttled.
This message is for the use case when an implementation has detected Memory is no longer Throttled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0143
User Action:
Information only; no action is required
• FQXSPMA2012I: An Over-Temperature Condition has been removed on the
[PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
SNMP Trap ID: 0
CIM Prefix: PLAT CIM ID: 0147
User Action: