Table 4-2: Input Parameters
Voltage U
Current I
Power P
Capacitance
C
i
Inductance L
Special Conditions for Safe Use(X):
1. When fitted with a transient suppression terminal block, the
equipment is not capable of withstanding the 500V insulation
test. This must be taken into account during installation.
2. The enclosure may be made of aluminium alloy and given a
protective polyurethane paint finish; however, care should be
taken to protect it from impact or abrasion if located in a Zone
0 area.
N1 ATEX Type n and Dust
Certificate:
Standards:
Markings:
Special Conditions for Safe Use(X):
1. This apparatus is not capable of withstanding the 500V
insulation test that is required by EN60079-15. This must be
taken into account when installing the apparatus.
2. Some variants of the equipment have reduced markings on
the nameplate. Refer to the Certificate for full equipment
marking.
4.5 
International
E7 IECEx Flameproof
Certificate:
Standards:
Quick Start Guide
HART
30V
i
200 mA
i
0.9 W
i
0.012 µF
0 mH
i
BAS00ATEX3167X; BAS01ATEX1427X
EN60079-0:2012, EN60079-15:2010, EN60079-31:2009
II 3 G Ex nA IIC T5 Gc (-40 °C ≤ T
II 1 D Ex t IIIC T50 °C T
IECEx KEM 06.0021X
IEC 60079-0:2011, IEC 60079-1:2014, IEC 60079-26:2014
Quick Start Guide
≤ +70 °C);
a
60 °C Da
500
25