July 2023
4. Process temperature limits shall be in accordance with
03031-1053.
5. Flameproof joints are not intended for repair.
I5 USA Intrinsic Safety (IS) and Nonincendive (NI)
Certificate
Standards
Markings
Specific Conditions for Use:
1. The Rosemount 3051G transmitter housing may contain
aluminum and is considered a potential risk ignition by impact
or friction. Care must be taken during installation and use to
prevent impact and friction.
2. The Rosemount 3051G with the transient terminal block
(Option code T1) will not pass the 500VRMS dielectric strength
test; this must be considered during installation.
3. Equipment evaluated for atmospheric pressure range between
80 kPa (0,8 bar) to 110 kPa (1,1 bar).
4. Maximum process temperature limits shall be in accordance
with 03031-1053.
C6 CSA Explosionproof, Dust Ignition-proof, Intrinsic Safety, and
Division 2
Certificate
Standards
Quick Start Guide
1053834
FM 3600: 2022, FM 3610: 2018, FM 3611: 2021,
ANSI/UL 61010-1-2019 Third Edition, ANSI/UL 60079-0:
2017, ANSI/UL 60079-11: 2013, ANSI-ISA-12.27.01–2022,
ANSI/UL 50E (First Edition)
IS: CL I GP ABCD T4
IS: CL II GP EFG; CL III T4
CL I ZN 0 AEx ia IIC T4 Ga
NI: CL I DIV 2 GP ABCD T4
-60 °C ≤ Ta ≤ +70 °C
OPTIONAL SINGLE SEAL
TYPE 4X, IP 68
INSTALL PER 03031-1024.
1053834
CAN/CSA C22.2 No. 61010-1-12, CAN/CSA C22.2 No.
94.2-20, CSA C22.2 No. 25-17, CAN/CSA C22.2 No.
30:20, CAN/CSA C22.2 No. 213-17 +UPD1 (2018) +UPD2
(2019) +UPD3 (2021), CAN/CSA C22.2 No. 60079-0:19,
Quick Start Guide