SPECIFICATIONS
Part No.
Input (nominal)
Input Power
Output Voltage
Output Current
Minimum Start Voltage
Back Drain
Charge Control
Battery Rescue Part 1 Battery voltage increases
>14.4V immediately
Battery Rescue Part 2 Battery voltage increases
>14.4V after stage 1
Soft Pulse 2-6.0V
Pulse Charge part 2 6.0-10.5V
Soft Start 10.5-12.0V 8 hour timeout then
transits to bulk
Bulk
Absorption
Absorption transits at following set points
Absorption timeout, transits to Analysis
Analysis
Float
Battery Range
Deep Cycle
Automotive
Marine
Size (mm)
Weight
8
AC040
240VAC, 50Hz
35.5W @ 6V, 63.5W @ 12V
6/12V
1, 4A
2.0V
2mA
500mA up 16.0V for
5 seconds, until voltage
reduces to 13.5V
500mA up to 17.0V,
if voltage drops to 13.5V
continue charging or
2 hour limit then fault.
0.8A for 1 second then turn of for 2 seconds 2 hour limit
then fault
Set current to 0.8A for 5 seconds then 2A for 5 seconds.
2 hour limit then fault.
1A
Set current to 13.6V (12V),
6.8V (6V)
Constant voltage (12V) 14.4V (Normal), 14.7V (Winter),
7.2V (6V)
Slow(1A): <0.5A
Fast(4A): <0.6A
Winter(4A): <0.6A
6V(4A): <0.6A
6 hours
60 second timeout, if battery drops <12.5V set F4 fault
(12V) 13.8V 2 min on,
2 min. off (6V) Cutout 7.2V,
Cut in 6.5V
7-80Ah
40-480CCA
55-650MCA
225 x 60 x 90
0.66kg
AC080
128.5W
12V
2, 8A
600mA up 16.0V for
5 seconds, until voltage
reduces to 13.5V
600mA up to 17.0V,
if voltage drops to 13.5V
continue charging or
2 hour limit then fault.
2A
Set current to 13.6V
Slow(2A): <0.5A
Fast(8A): <1.2A
Winter(8A): <1.2A
(12V) 13.8V 2 min on,
2 min. off
14-160Ah
80-1000CCA
110-1300MCA
250 x 68 x 95
0.87kg
Need help?