SPECIFICATIONS

Table 1 Line Mode Specifications
MODEL
Input Voltage Waveform
Nominal Input Voltage
Low Loss Voltage
Low Loss Return Voltage
High Loss Voltage
High Loss Return Voltage
Max AC Input Voltage
Max AC Input Current
Nominal Input Frequency
Low Loss Frequency
Low Loss Return Frequency
High Loss Frequency
High Loss Return Frequency
Output Short Circuit Protection
Efficiency (Line Mode)
Transfer Time
Output power de-rating:
When AC input voltage under 170V the
output power will be de-rated.
LV 6548
Sinusoidal (utility or generator)
120Vac
90Vac± 7V (UPS)
80Vac± 7V (Appliances)
100Vac± 7V (UPS);
90Vac± 7V (Appliances)
140Vac± 7V
135Vac± 7V
150Vac
60A
50Hz / 60Hz (Auto detection)
40± 1Hz
42± 1Hz
65± 1Hz
63± 1Hz
Line mode: Circuit Breaker
Battery mode: Electronic Circuits
>95% ( Rated R load, battery full charged )
10ms typical (UPS);
20ms typical (Appliances)
Output Power
Rated Power
50%
Power
90V
170V
42
280V
Input Voltage