Installing A Wall Mounted Termination 5''/10 - Montigo Phenom PL38 Installation & Maintenance Manual

Hide thumbs Also See for Phenom PL38:
Table of Contents

Advertisement

Installing a Wall Mounted Termination 5''/10''
FOR P52 AND PL52 UNITS ONLY
This section applies to installations where the direct vent termination
will be wall mounted. NOTE: If subject to a highly corrosive environment
i.e. seaside, Montigo recommends using stainless steel termination.
Installation of termination with built in frame under 8' from the top
of the unit.
A Termination with a built-in frame is installed during framing of a
structure.
1. Frame the termination opening to 16" x 16".
2. Install exterior sheathing to the structure framing.
3. Fasten the termination to the sheathing using a minimum of 4 screws.
Framing
Framing
16"
Exterior
Exterior
Sheathing
Sheathing
RHS 104
RHS 104
(Not Shown)
(Not shown)
16"
Figure 7.g Installing a RTO-4F termination.
16
"
Fastening Hardware,
Fastening Hardware,
minimum 4-screws
minimum 4-screws
RTO-4F (5"/10")
RTO-4F (5"/10")
Termination
Termination
Installation
XG0199 - 170223