Section 3-3-1: Venting Layout: Wall Mounted Termination

Top Venting Graph P38, PL38:

Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar
to the wall flange of the termination. Plot on the Venting Graph Figure
8 or 8b with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Selection of components and details of venting layout should adhere
to the following guidelines:
• Vent terminations must not be recessed in walls or siding.
• For Heat Shield requirements see Section 3-3 on page 14.
• Once the proposed venting layout has been determined refer to
Figure 8, 8b, 8c to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
• All measurements for vertical or horizontal runs are measured from
center of the vent pipe.
• Venting runs must fall within the limits set by the venting graph,
see Figure 8 or 8b.
Wall mounted Terminations:
The following details are some possible configurations for Wall mounted
terminations. See below.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 144", this would be an
acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 36" and the horizontal run
to the wall flange of the vent termination is 84", this would not be an
acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this
would not be an acceptable installation.
XG0199 - 170223
PROPANE GAS VENT RUN
132
120
Acceptable vent run
within non-shaded area.
108
96
84
72
60
63''
48
16''
36
24
12
0
0
12
24
36
48
60
Horizontal Run (In.)
Figure 8. PL38DF* Propane Top Vent Venting Graph for wall mounted terminations.
NATURAL GAS VENT RUN
132
120
Acceptable vent run
within non-shaded area.
108
96
84
72
60
48
36
39''
24
44''
12
0
0
12
24
36
48
60
Horizontal Run (In.)
Figure 8.b PL38DF* NG Top Vent Venting Graph for wall mounted terminations.
44" Max. for minimum vertical (NG)
Flex section
Flex section
Hearth
Hearth
Figure 8.c Top Vented, wall mounted Multi-elbow installation. See Venting Graph for Top vent,
wall mounted terminations, Figure 8 or 8.b
Installation
A
C
B
Unacceptable vent run
within shaded area.
72
84
96
108
120
132
144
156
168 180
A
C
B
Unacceptable vent run
within shaded area.
72
84
96
108
120
132
144
156
168 180
44" Max. (NG)
16" Max. (LP)
16" Max. for minimum
vertical (Propane)
Heat
Heat Shield
Shield
Termination
Termination
39" Min. (NG)
39" Min. (NG)
63" Min. (Propane)
63" Min. (LP)
Exterior
Exterior
Wall
Wall