FAULT
E:32-00 will light up alternately or
indicator for water supply lights up.
E:34-00 will light up alternately.
E:61-02 will light up alternately.
E:61-03 will light up alternately. Wa-
ter is not drained.
E:90-01 will light up alternately.
E:92-40 will light up alternately.
CAUSE
The filters in the water connection
of the supply or AquaStop hose are
blocked.
Water is continuously running into
the appliance.
Wastewater pump is blocked.
Cover of the wastewater pump is
loose
Wastewater hose is blocked or
kinked.
Siphon connection is still sealed.
Cover of the wastewater pump is
loose.
Mains voltage is too low.
Filters are soiled or blocked.
TROUBLESHOOTING
The flow rate must be at least 10 l/min when
the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
Remove the filter from the supply hose
5.
Clean the filter.
6.
Re-insert the filter in the supply hose.
7.
Screw the water connection back on.
8.
Check the water connection for leaks.
9.
Restore the power supply.
10.
Switch the appliance on.
11.
Turn off the water tap.
1.
Call Customer Service.
2.
Clean the wastewater pump.
→ "Clean wastewater pump", Page 35
Secure the cover of the "Wastewater pump "
→ Page 35 so it clicks into position.
Reposition the wastewater hose without
1.
kinks.
Remove residues.
2.
Check the connection to the siphon and open
if necessary.
Secure the cover of the "Wastewater pump "
→ Page 35 so it clicks into position.
This is not a fault on the appliance.
Contact an electrician.
1.
Have the mains voltage and electrical installa-
2.
tion checked by an electrician.
Clean the filters.
→ "Cleaning filters", Page 25