Parameter selection
By pressing the button (19) different values can be shown and changed. Use the knob (7) to
change the values. The sequence is:
1.
Set current value.
2.
Measured current value.
3.
Measured voltage value.
Set parameter
The set indicator (4) will be lit when a displayed value can be changed. It cannot be changed
from the panel when a remote control is activated. Trying to change a value while in
measured value mode will result in automatically move to set current value mode.
The set indicator (4) is off when measured values are shown.
Weld parameters
The weld parameters are stored for pulse and no pulse respectively. The values are changed
when changing between pulse and no pulse.