Venting Arrangements - Allowable Vertical Terminations For Hz54E-Lp - Regency Fireplace Products HZ54E Owners & Installation Manual

Table of Contents

Advertisement

installation
Venting Arrangements -
The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
o
venting systems for propane. Two 45
90
elbow. Maximum of four 45
o
Please note min. 1 foot between 90
elbows is required.
Vent must be supported at offsets.
Firestops are required at each floor level and
whenever passing through a wall.
Maintain clearances to combustibles as listed in
the "Clearances" section.
Refer to the "Vent Restrictor Position" section for
details on how to change the vent restrictor from
the factory setting of Set 1 to Set 4 or Set 5
if required.
Note: Must use optional flue adaptor when using
Rigid Pipe (Part # 770-994).
36
Regency Horizon ® HZ54E-11 Gas Fireplace
|
Allowable Vertical Terminations for HZ54E-LP
elbows, with rigid/flex pipe
elbows equal to one
o
elbows allowed.
o
o
2
4
0
40
38
36
34
32
30
Vent Restrictor on Set 5
28
26
24
22
Vent Restrictor on Set 4
20
18
16
14
12
10
8
6
4
2
0
Max. 10' (3m)(centerline to centerline)
Minimum length of pipe
between elbows 12" (305mm)
Horizontal (Feet)
8
6
10
12
Vent Restrictor on Set 1
(factory setting)
14
18
16
20