Hz54E-Ng; Venting Arrangements - Allowable Horizontal Terminations For Hz54E-Lp - Regency Fireplace Products HZ54E Owners & Installation Manual

Table of Contents

Advertisement

Venting Arrangements -
nations for HZ54E-NG
The diagram shows all allowable combinations of vertical runs with horizontal
terminations, using one 90
o
(two 45
Note: Must use optional rigid pipe adapter (Part# 770-994) when
using Rigid Pipe Venting Systems.
0
2
4
18
Vent Restrictor
on Set 3
16
14
Vent Restrictor
on Set 2
12
10
8
6
4
44" (1118mm)
2
Minimum Height
Requirement
0
VENT RESTRICTOR SETTING:
Vent restrictor factory set, no adjustment required unless otherwise
indicated.
Refer to the "Vent Restrictor Position" section for details on how to change
the vent restrictor from the factory setting of Set 1 to Set 2 or Set 3 if required.
®
Note: Regency
Direct Vent System (Flex) is only approved
for horizontal terminations.
Maintain clearances to combustibles as listed in "Clearances"
section
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing
through a wall.
A wall thimble is mandatory for all horizontal terminations due
to high temperatures.
Allowable Horizontal Termi-
o
elbows equal one 90
o
elbow).
Horizontal (Feet)
6
8
14
10
12
Vent Restrictor
on Set 1
(factory setting)
Venting Arrangements -
nations for HZ54E-LP
The diagram shows all allowable combinations of vertical runs with horizontal
terminations, using one 90
Note: Must use optional rigid pipe adapter (Part# 770-994) when
using Rigid Pipe Venting Systems.
16
18
20
18
16
14
12
10
8
6
4
2
0
VENT RESTRICTOR SETTING:
Vent restrictor factory set, no adjustment required unless otherwise
indicated.
Refer to the "Vent Restrictor Position" section for details on how to change the
vent restrictor from the factory setting of Set 1 to Set 4 if required.
Note: Regency
horizontal terminations.
Maintain clearances to combustibles as listed in "Clearances" section
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing
through a wall.
A wall thimble is mandatory for all horizontal terminations due to
high temperatures.
Allowable Horizontal Termi-
o
(two 45
o
elbows equal one 90
Horizontal (Feet)
0
2
4
6
8
Vent Restrictor
on Set 4
Vent Restrictor
on Set 1
(factory setting)
44" (1118mm)
Minimum Height
Requirement
®
Direct Vent System (Flex) is only approved for
Regency Horizon ® HZ54E-11 Gas Fireplace
installation
o
elbow).
14
16
10
12
18
31
|