4 INSTALLATION
4.3

Mains supply

NOTE!
Rogue ES 150i and ES 180i do not comply with IEC 61000-3-12. If it is connected to
a public low voltage system, it is the responsibility of the installer or user of the
equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment may be connected.
The power source will automatically adjust to the supplied input voltage. Make sure that it is
protected by the correct fuse rating. A protective ground connection must be made, in
accordance with regulations.
Rating plate with supply connection
1.
data.
Recommended fuse sizes and minimum cable area for the Rogue ES 150i, ES 180i
Supply voltage
Electrical cable area
Maximal current rating
I
MMA/Stick (SMAW)
max
I1eff MMA/Stick (SMAW)
Fuse anti-surge type D MCB
0463 732 201
Rogue ES 150i
230 VAC
2
2.5 mm
30 A
15 A
20 A
- 13 -
ES 180i
230 VAC
2
2.5 mm
36 A
16 A
25 A