8.2.13 Display Low Cutoff

When low cutoff is set in 8.2.12 "Low Cutoff," this function determines whether to use the low cutoff
processing for displayed values.
You can select the display low cutoff setting from the items in the table below.
● Display low cutoff setting function
For example, if the low cutoff is set to 10% and the indicated value of the input from the detector is
5%, the displayed value on the screen becomes as shown below.
You can check or change the display low cutoff as described below.
The following is an example to change the setting from LINEAR to LOW CUT.
Switch operation
STEP1
STEP2
STEP3
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Selection items
Low cutoff processing is not used for displayed
LINEAR
values.
LOW CUT
Displayed values are processed with low cutoff.
Display low cutoff
LINEAR
5.0%
LOW CUT
0.0%
Display example
E:LOW CUT
1 CUT VAL
2 DSPL SET
3 EXIT
ESC
DSPL SET
LINEAR
ESC
DSPL SET
LINEAR
DSPL SET
LOW CUT
- 77 -
Displayed values
Displayed value
Description
Select "DSPL SET" from the setting item
selection menu.
The currently set low cutoff setting
(LINEAR in this example) appears.
Then push
.
Pushing
ESC
returns you to the setting
menu.
The switches at the bottom change.
(
At the same time, the cursor appears.
(The item indicated by the cursor is
highlighted.)
Then push
You can continue to change the setting item.
Push
to change the selection
items.
: Selected item is scrolled up.
: Selected item is scrolled down.
When the desired item is selected, push
to set the item temporarily.
6 F 8 A 0 9 2 8
are shown.)
.