Output performance of multi-range functions
(1) Automatic selection of unidirectional flow multi-range with an internal signal
Output (%)
125
100
Range 4
Hysteresis
(0~25%)
0
Reverse
0
Range output No.1
Range output No.2
・ Current output when fluid flows in the reverse direction is the value set for the output low limit
(any one of 2.4/3.2/4.0mA).
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Range 3
Forward direction
ON
OFF
ON
- 117 -
Range 1
Range 2
Flow rate direction
ON
OFF
OFF
6 F 8 A 0 9 2 8
20mA
4mA