ENTERPRISE
4300/4300R
In-Building Cell Signal Amplifier
With Frequency-Specific Outside Antenna Ports and
LTE Connected Remote Monitoring
Installation Guide
wilsonpro.com
866.294.1660

Advertisement

loading

Summary of Contents for Wilson Electronics WILSONPRO ENTERPRISE 4300

  • Page 1 A Wilson Electronics Brand ENTERPRISE 4300/4300R In-Building Cell Signal Amplifier With Frequency-Specific Outside Antenna Ports and LTE Connected Remote Monitoring Installation Guide wilsonpro.com 866.294.1660...
  • Page 2: Table Of Contents

    Index Package Contents About The Enterprise 4300 & 4300R Key Features Post Install Setup Menu System Safety Guidelines Specifications Warranty...
  • Page 3: Package Contents

    Package Contents Enterprise 4300 SKU 460152 & 460152F Enterprise 4300 Amplifier 100 ft. Wilson400 Cable (qty. 5) Wide Band Directional Antenna (qty. 1) 50 Ohm Lightning Surge Protector (qty. 1) Dome Antenna (qty. 4) 2 ft. Wilson400 Cable (qty. 1) Enterprise 4300R SKU 460153 &...
  • Page 4: About The Enterprise 4300 & 4300R

    Enterprise 4300 & 4300R In-Building Cell Signal Amplifier Systems Frequency-specific “split mode” option, facilitating separate outdoor antennas for different bands, resulting in improved indoor coverage. Remote system monitoring. Connects to WilsonPro Cloud service via internal, pre-activated LTE modem. High max uplink power (up to +26 dBm): will reach far-away cell tower.
  • Page 5 The Enterprise 4300 & 4300R cell signal amplifier systems also incorporates Wilson Electronics’ state-of-the-art XDR (eXtended Dynamic Range) technology that prevents signal overload conditions which can, in accordance with regulations, force the amplifier to shut down.
  • Page 6: Key Features

    Features Extended Dynamic Range (XDR) for continuous connectivity: XDR lets the Enterprise 4300 & 4300R systems work with an incoming signal and never shuts down due to a strong outside signal. Simple Wall-Mount & Rack Mount Installation: An indoor and outdoor port(s) are located on top of the amplifier for easy antenna connections, while an exposed mounting flange on each amplifier provides for simple installation.
  • Page 7: Post Install Setup

    Post Install Setup The Enterprise 4300 & 4300R systems are designed with advanced internal programming, which allows it to automatically adjust for a variety of conditions, while still amplifying weak signals. THE SERVER PORT ANTENNAS WILL BE USED TO PROVIDE COVERAGE TO DIFFERENT AREAS WITHIN A BUILDING AND WILL BE INSTALLED WITH A MINIMUM OF 10 METERS...
  • Page 8: Menu System

    Menu System The Enterprise 4300 & 4300R takes about 8 seconds to boot up. Once boot up is complete, the home screen will appear, showing the amplification and status of each port and band. Home Screen Start Up Screen Band Menu Color Description A solid green light indicates that a band is operating correctly with maximum allowable gain.
  • Page 9 (MENU SYSTEM cont.) A red light indicates a band has been shut down because of a severe oscillation condition or repeated oscillation. Reposition antennas (increase separation between indoor and outdoor antennas, and point in opposite directions) and then reboot (turn the unit off &...
  • Page 10 Settings Screen Tap ‘Settings Icon’ to view the Settings Screen. There are 5 Settings Screens represented by “tabs”. Tap the tab heading to view each Settings Screen. Note: Bands and Ports are disabled or enabled from the Cloud or Local Configuration Utility only. IN-BUILDING CELL SIGNAL AMPLIFIER ENTERPRISE 4300 &...
  • Page 11 (MENU SYSTEM - SETTINGS SCREEN cont.) Ethernet Settings Tab Modem Settings Tab ENTERPRISE 4300 & 4300R IN-BUILDING CELL SIGNAL AMPLIFIER...
  • Page 12 (MENU SYSTEM - SETTINGS SCREEN cont.) Cloud Communication Settings Tab Note: The Reset Local Comm button (button name will likely change) is used in case the user has configured the amplifier such that the Local Configuration Utility is not accessible, e.g., if the communication preferences are set to “LTE Only”.
  • Page 13 (MENU SYSTEM - SETTINGS SCREEN cont.) Split Mode Configuration Split Mode is configured from the Local Configuration Utility and should be sent when using separate Donor/Outside Antennas for Band 4/25, Band 5, and Band 12/13. To go back to the Home Screen top on the Home Icon (in the lower right corner). ENTERPRISE 4300 &...
  • Page 14 Band Status Screens To view specific band information (such as the strength of the received uplink & down- link signal, outside signal strength, and amplifier gain status) tap the desired band on the home screen. Oscillation Example IN-BUILDING CELL SIGNAL AMPLIFIER ENTERPRISE 4300 &...
  • Page 15 (MENU SYSTEM - SETTINGS SCREEN cont.) Shutdown Example ENTERPRISE 4300 & 4300R IN-BUILDING CELL SIGNAL AMPLIFIER...
  • Page 16 Connectivity Status Screens Ethernet Status Icon The three icons in the upper right provide status related to the Ethernet connection, Cloud connection, and USB device (if inserted). Cloud Status IN-BUILDING CELL SIGNAL AMPLIFIER ENTERPRISE 4300 & 4300R...
  • Page 17 (MENU SYSTEM - CONNECTIVITY STATUS SCREENS cont.) USB Status ENTERPRISE 4300 & 4300R IN-BUILDING CELL SIGNAL AMPLIFIER...
  • Page 18: Safety Guidelines

    To uphold compliance with network protection standards, all active cellular devices must maintain at least 6 feet of separation distance from Panel and Dome antennas. Use only the power supply provided in this package. Use of a non-Wilson Electronics product may damage your equipment.
  • Page 19 Antenna Kit Options The following accessories are certified by the FCC to be used with the ENTERPRISE 4300/4300R. 314411 859902 Wide Band Directional Antenna (Outside Antenna) 50 Ohm Lightning Surge Protector 952300 952302 100 ft. Wilson400 Cable (for Outside Antenna) 2 ft.
  • Page 20: Specifications

    Specifications Model Number 460152 / 460152F / 460153 / 460153F FCC ID PWO460052 / PWO460052 / PWO460053 / PWO460053 IC ID 4726A-460052 / 4726A-460052 / 4726A-460053 / 4726A-460053 Connectors N-Connectors Antenna Impedance 50 Ohms Frequency 698-716 MHz, 729-756 MHz, 777-787 MHz, 824-894 MHz, 1850-1995 MHz, 1710-1755/2110-2155 MHz Power output for single cell Band12/17 Band13...
  • Page 21: Warranty

    MARKETING APPROVAL: Installer and end customer hereby grants to Wilson Electronics the express right to use installers or end customers company logo in marketing, sales, financial, and public relations materials and other communications solely to identify Customer as a Wilson Electronics customer.
  • Page 22 Notes support.wilsonpro.com 866.294.1660 NEED HELP? IN-BUILDING CELL SIGNAL AMPLIFIER ENTERPRISE 4300 & 4300R...
  • Page 23 Notes support.wilsonpro.com 866.294.1660 NEED HELP? ENTERPRISE 4300 & 4300R IN-BUILDING CELL SIGNAL AMPLIFIER...
  • Page 24 Copyright © 2016 Wilson Electronics. All rights reserved. Copyright © 2019 Wilson Electronics. All rights reserved. Wilson Electronics products covered by U.S. patent(s) and pending application(s) Wilson Electronics products covered by U.S. patent(s) and pending application(s) For patents go to: weboost.com/us/patents For patents go to: weboost.com/us/patents...