5. EEPROM [C]
When installing the new EGB
1. Remove the EEPROM from the old EGB.
2. Install it on the new EGB with the mark [A] pointing to the left side of the board after you replace the
EGB.
3. Replace the EEPROM if the EEPROM on the old EGB is defective.
• Keep the EEPROM away from any objects that can cause static electricity. Static electricity can
damage EEPROM data.
• Make sure that the EEPROM is correctly installed on the EGB.
Electrical Components