Kyocera PE-MF2 Service Manual page 159

Table of Contents

Advertisement

Scan Maintenance
ADF Main Reg.
ADF Sub Reg.
Regist Adjust
Flatbed Main Reg.
Flatbed Sub Reg.
ADF Main Reg.
ADF Sub Reg.
Size Adjust
Flatbed Main Reg.
Flatbed Sub Reg.
Fax Maintenance
RX Level
Modem Settings
TX Level
Cable Equalizer
Adjusts the ADF Scan main-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan sub-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan main-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan sub-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan main-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Sets the reception level.
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Sets the transmission level.
[0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm
/ -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm
/ -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm
/ -14 dBm/ -15 dBm]
These selectors are used to improve the pass-band
characteristics of analogue signals on the telephone line.
[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]
Service Menu
4
41

Advertisement

Table of Contents
loading

Table of Contents