Engine Maintenance
Horiz.Bypass
Vert.Bypass
Registration
Horiz.Dup.Back
Vert.Dup.Back
Reset Count
Resets counters to factory defaults.
Clear Count
Clears the Scanner and Jam Counters.
Resets the maintenance counter for the fusing unit.
Replace Fuser
This item appears only when the fusing unit life is almost expired or has expired.
This clears all counters except "Full Color" and "Black and White" in the total
counter.
Init Engine EEPROM
When you execute "Init Engine EEPROM", the engine EEPROM is initialized.
Turn the machine power off/on after you change this setting.
Displays only
1: MF2b
Model
2: MF2c
Displays the current model in a dropdown list.
Do not change this setting (Designed for Factory Use).
Adjusts the horizontal registration for the bypass tray. If the
machine settings are reset to the factory defaults, this value
does not change.
[-15 to 15 / 0 (Default) / 4 mm/step]
Adjusts the vertical registration for the bypass tray. If the
machine settings are reset to the factory defaults, this value
does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Adjusts the horizontal registration for the back side in
duplex mode. If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 4 mm/step]
Adjusts the vertical registration for the back side in duplex
mode. If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Service Menu
4
39