Cooling Requirements; Laser Safety; Installation Tools - HP 3100-48 v2 Installation Manual

Table of Contents

Advertisement

Cooling requirements

The built-in fan in the 3100-48 v2 switch blows air from the left to the right of the chassis for heat
dissipation, as shown in
Figure 3 Airflow through the 3100-48 v2 switch
(1) Air intake
For adequate heat dissipation, plan the installation site according to the airflow of your switch, and
adhere to the following requirements:
Leave a clearance of at least 10 cm (3.94 in) around the air intake and exhaust vents.
Consider the heat dissipation of the installation site when determining air-conditioning
requirements to ensure that cool air can enter the switch.
Make sure the hot air generated by equipment at the bottom of the rack is not drawn in the intake
of the equipment above.
The installation site has a good cooling system.

Laser safety

The 3100-48 v2 switch is a Class 1 laser device.
CAUTION:
Do not stare into any fiber port when the switch has power. The laser light emitted from the optical fiber
may hurt your eyes.

Installation tools

Flat-blade screwdriver
Phillips screwdriver
ESD wrist strap
All these installation tools are user supplied.
Figure
3.
1
(2) Air exhaust
4
2

Advertisement

Table of Contents
loading

Table of Contents