Becker M04 Assembly And Operating Instructions Manual

P5...l120 roller shutter and sun protection drives with mechanical limit switch

Advertisement

P5...L120
Model: M04
Assembly and Operating Instructions
en
Roller shutter and sun protection drives with
mechanical limit switch
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 300 332 0h     07/09/2016   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M04 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Becker M04

  • Page 1 P5...L120 Model: M04 Assembly and Operating Instructions Roller shutter and sun protection drives with mechanical limit switch Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference.
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable ..........................  6 Disassembling the plug-in connecting cable for tubular drives dia.
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • For use with roller shutters • For use with sunblinds • Easy limit switch setting on the drive • Compatible with all of the drive manufacturer's control units for roller shutters and sunblinds •...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed by authorised specialists, in particular qualified electricians.
  • Page 5 • Moving parts of drives must be installed at a height of over 2.5 m above floor level or any other surface from which access to the drive is gained. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters and sun protection systems. We recommend using drives with more than 17 rpm only in sun protection systems (screens). When mounting connection parts on the drive PXX/XX dia. 35 mm, only use screws EJOT Delta PT 40x12 WN 5454 Torx (9900 000 545 4).
  • Page 7: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 35

    Disassembling the plug-in connecting cable for tubular drives dia. 35. Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug.
  • Page 8: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 45 And Dia. 58

    Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
  • Page 9: Installation

    Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
  • Page 10: Disassembling The Drive Adapter With Safety Catch On The Drive Shaft

    Disassembling the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool, Item no. 4930 300 606 0 Disassembly with long nose pliers Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Securing the drive against axial displacement In order to secure the drive against axial displacement, we recommend screwing the drive adapter to the tube.
  • Page 11: Fixing The Drive Adapter To The Barrel Dia. 35 And Dia. 45 And Dia. 58

    Fixing the drive adapter to the barrel dia. 35 and dia. 45 and dia. 58 Size of drive Diameter of barrel Torque Fastening screws [mm] [mm] max. [Nm] for drive adapter (4 pc.) dia. 35 40 mm plastic drive adapter Self-tapping screw dia.
  • Page 12 Assemble the tubular drive with the relevant ring (1) and drive adapter (2). If the ring has several grooves, select the groove which is a perfect fit and push the ring (1) onto the thrust ring. Insert the tubular drive with the pre-assembled ring (1) and drive adapter (2) into the tube to achieve a form fit.
  • Page 13: Setting The Limit Positions

    Setting the limit positions Upper limit position Lower limit position Lower limit position Upper limit position Setting the lower limit position 1. Before the shading solution is fixed to the barrel, let the drive run DOWN until it switches off automatically. 2.
  • Page 14: Information For The Electrician

    This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc- ling or disposal for this product in your country. The packaging material must be disposed of properly. Maintenance These drives are maintenance-free. Technical data dia. 35 Model P5-20-M04 P5-30-M04 P9-16-M04 P13-9-M04 Type P5/20C M P5/30C M...
  • Page 15: Technical Data Dia. 45

    Technical data dia. 45 Model R8-17-M04 R12-17-M04 R20-17-M04 Type R8/17C M R12/17C M R20/17C M Rated torque [Nm] Output speed [rpm] Limit switch range 38 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.45...
  • Page 16: What To Do If

    Model L70-17-M04 L80-11-M04 L80-17-M04 L120-11-M04 Type L70/17C M L80/11C M L80/17C M* L120/11C M Rated torque [Nm] Output speed [rpm] Limit switch range 36 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 1.90 1.40 2.10 1.90 Operating mode S2 4 min Degree of protection IP 44...
  • Page 17: Sample Wiring Diagrams

    Sample wiring diagrams Control via a single switch/button Central, group and individual control using Centronic UnitControl UC42 Central Control unit Mains 230 V / 50 Hz Central cable 230 V / 50 Hz (connection to further control units) Group 230 V / 50 Hz Individual Individual 230 V / 50 Hz...
  • Page 18: Declaration Of Conformity

    Declaration of conformity...