6.0
Fault Diagnosis
6.1
Gas Combi-Sets
6.1.1
Flame Cannot Be Ignited
6.1.2
The Flame Goes Out When Using A Low Setting
6.1.3
Uneven / Flickering Flame
6.1.4
Unusual Color Flames
6.1.5
Flame not visible around the entire burner or uneven flames
6.1.6
Flame Continuously Goes Out about 30 seconds after Igniting
Check for:
Dirty burner head parts. / Parts not seated correctly.
Dirty Ignition Electrode. / Faulty Ignition Electrode
Appliance is damp (spark current grounding within the unit)
Faulty Transformer.
Faulty Ignition Switch.
Incorrect Jets for type of gas supply.
Mis-Adjusted Air Intake.
Dirty burner head parts.
Incorrect Simmer Adjustment Jets
Dirty burner head parts. / Parts not seated correctly.
Mis-Adjusted Air Intake.
Gas pressure not in specification.
Faulty Gas Regulator.
Dirty burner head parts.
Contaminated Gas Supply.
Dirty burner head parts. / Parts not seated correctly.
Carefully inspect all holes in burner ring for contamination
(i.e. food residues)
Dirty burner head parts. / Parts not seated correctly.
Dirty, damaged or defective Thermocouple.
Loose connections on Thermocouple.
Thermocouple routed incorrectly, making contact with
appliance frame.