Connections; Primary Electrical Input Connections - ESAB Jesse James SIGNATURE Series Instruction Manual

Portable plasma cutting system
Table of Contents

Advertisement

section 3
electric shocK can Kill! precaution-
ary measures should be taken to provide
maximum protection against electrical
shock. Be sure that all power is off by
opening the line (wall) disconnect switch
and by unplugging the power cord to the
unit when connections are made inside of
the power source.
Be sure that the power source is properly
configured for your input power supply. Do
not connect a power source configured for
208/230 V to a 460 V input power supply.
Damage to the machine may occur.
All manuals and user guides at all-guides.com
3.4

connections

3.4.1
primarY electrical input connections (figure 3.1)
A line (wall) disconnect switch with fuses or circuit breakers should be provided at
the main power panel (see Fig. 3-1 and Table 3-1 for fuse sizes). The input power
cable of the console may be connected directly to the disconnect switch or you
may purchase a proper plug and receptacle from a local electrical supplier. If using
plug/receptacle combination, see Table 3-1 for recommended input conductors for
connecting receptacle to line disconnect switch.
table 3.1. recommended sizes for input conductors
rated input
Volts
amp
208
35
230
32
* Sized per National Code for 80°C rated copper conductors @ 30°C ambient. Not more than three
conductors in raceway or cable. Local codes should be followed if they specify sizes other than those
listed above.
CUSTOMER FUSED LINE DISCONNECT SWITCH
(See Table 3.1 and WARNING in regards to chassis
ground in Section 3.4.)
figure 3.1 customer fused line Disconnect and receptacle
10
and line fuses
input & gnD
conductor
phases
cu/aWg*
1
No. 10
1
No. 10
Factory supplied primary
power cable with plug.
installation
fuse size
amps
50
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powercut 650

Table of Contents