4.3 Output specification
Normal transistor output:
External power
Circuit insulation
Action indicator
Max
Resistant load
load
Inductive load
Lamp load
Mini load
Response
OFF→ON
time
ON→OFF
Note: When the high-speed pulse output function is used, the controller can output 100KHz~200KHz
pulses, but it cannot ensure that all the servos operate normally.
Please connect a resistance of about 500 ohms between the output end and the 24V power supply.
4.4 Transistor output processing
Normal transistor output
•
Output Terminals
The transistor output of the controller unit has 2~3 common outputs.
•
External Power Supply
Please use DC5~30V power supply to drive the load.
•
Circuit Isolation
Inside PLC, we use photoelectric couplers to isolate between internal circuits and output
transistors; besides, the COM terminal blocks are separate from each other.
Below DC5~30V
Light coupling insulation
LED
0.3A
7.2W/DC24V
1.5W/DC24V
DC5V 2mA
Below 0.2ms
Below 0.2ms