7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.

Optional Quick Installation Method

The following quick installation method may be used to install the chassis onto a
rack.
Installing the Chassis into a Rack
1. Install the whole rail assembly onto the rack as described on page 2-7.
2. Release the inner rail without retracting the middle rail.
3. Install the inner rails on the chassis as previously described on page 2-6.
4. Install the chassis onto the middle rail as described in the previous section.
Warning: Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
2-6

Checking the Serverboard Setup

After you install the 2027TR-D70RF(+) in the rack, you will need to open the unit
to make sure the serverboard is properly installed and all the connections have
been made.

Accessing the Inside of the System

Before operating the system for the first time, it is important to remove the protective
film over the cover of the chassis, in order to allow for proper ventilation and cooling.
Removing the Chassis Cover and Protective Film (Figure 2-7)
1. Confirm that the power cord has been removed from the rear of both power
supplies.
2. Peel off the protective film covering the top cover and the top of the chassis
Chapter 2: Server Installation
2-9