  • Page 1 UPER ® UPER ERVER 2027GR-TR2 2027GR-TRT2 2027GR-TRH2 2027GR-TRHT2 USER’S MANUAL Revision 1.0...
  • Page 2 The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
  • Page 3 Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 2027GR-TR2/ TRT2/TRH2/TRHT2. Installation and maintenance should be performed by experi- enced technicians only. The SuperServer 2027GR-TR2/TRT2/TRH2/TRHT2 is based on the SC218GHTS- R1K66BP 2U server chassis and the Super X9DRG-HF+II/X9DRG-HTF+II serverboard.
  • Page 4 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRG-HF+II/X9DRG-HTF+II serverboard, including the locations and functions of connectors, headers and jump- ers. Refer to this chapter when adding or removing processors or main memory and when reconfi...
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Table of Contents Chapter 1 Introduction Overview ......................1-1 Serverboard Features ..................1-2 Processors ...................... 1-2 Memory ......................1-2 Serial ATA ....................... 1-2 PCI Expansion Slots ..................1-2 Onboard Controllers/Ports ................1-3 IPMI ......................... 1-3 Server Chassis Features ................
  • Page 7 Table of Contents Power ......................3-2 Control Panel LEDs ..................3-2 Power ......................3-2 HDD ......................... 3-2 NIC1 ........................ 3-3 NIC2 ........................ 3-3 Information LED ....................3-3 Power Failure ....................3-4 Drive Carrier LEDs ..................3-4 Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............
  • Page 8 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Serverboard Details ..................5-11 X9DRG-HF+II/ X9DRG-HTF+II Quick Reference ......... 5-12 Connector Defi nitions ................... 5-14 Jumper Settings .................... 5-20 Onboard Indicators ..................5-22 5-10 SATA Ports ....................5-23 5-11 Installing Software ..................5-24 SuperDoctor III ....................5-25 5-12 Onboard Battery ....................
  • Page 9: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 2027GR-TR2/TRT2/TRH2/TRHT2 is a GPU-optimized server comprised of two main subsystems: the SC218GHTS-R1K66BP 2U server chassis and the X9DRG-HF+II/X9DRG-HTF+II serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
  • Page 10: Serverboard Features

    If you have any questions, please contact our support team at: support@supermicro.com Serverboard Features At the heart of the SuperServer 2027GR-TR2/TRT2/TRH2/TRHT2 server is the X9DRG-HF+II/X9DRG-HTF+II , a dual processor serverboard based on the Intel C602 chipset. Below are the main features of the X9DRG-HF+II/X9DRG-HTF+II .
  • Page 11: Onboard Controllers/Ports

    Chapter 1: Introduction Onboard Controllers/Ports The rear I/O ports include a VGA (monitor) port, two USB 2.0 ports, two Gb Eth- ernet LAN ports (plus two 10 Gb ports on the X9DRG-HTF+II) and one dedicated IPMI LAN port. IPMI IPMI (Intelligent Platform Management Interface) is a hardware-level interface speci- fi...
  • Page 12: Gpu Subsystem

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual GPU Subsystem The 2027GR-TR2/TRT2/TRH2/TRHT2 server represents one of Supermicro's massively parallel processing multiple-GPU servers, with support for up to six GPUs. NVIDIA® Kepler™ GPUs place this system at the forefront of today's GPU computing solutions. Please refer to the NVIDIA web site (www.nvidia.com) for details on Kepler GPUs.
  • Page 13 Chapter 1: Introduction Figure 1-1. Intel C602 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #1-8 #1-7 #1-6 #0-8 #1-5 #0-7 #1-4 #0-6 #1-3 #0-5 #1-2 #0-4 #1-1 CPU 2 CPU 1 CPU 1 #0-3 Sandybridge-EP...
  • Page 14: Contacting Supermicro

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 15: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your system up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled.
  • Page 16: Warnings And Precautions

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl...
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
  • Page 18: Installing The System Into A Rack

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Installing the System into a Rack This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided.
  • Page 19: Locking Tabs

    Chapter 2: Server Installation Locking Tabs Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack. This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing.
  • Page 20: Installing The Inner Rails On The Chassis

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Inner Rails Figure 2-3. Installing the Inner Rails Installing The Inner Rails on the Chassis Installing the Inner Rails 1. Confi rm that the left and right inner rails have been correctly identifi ed. Place the inner rail fi rmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
  • Page 21: Installing The Outer Rails On The Rack

    Chapter 2: Server Installation Figure 2-4. Extending and Releasing the Outer Rails Installing the Outer Rails on the Rack Installing the Outer Rails 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail. 3.
  • Page 22: Standard Chassis Installation

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Ball-Bearing Shuttle Figure 2-5. Installing the Chassis into a Rack Note: fi gure is for illustrative purposes only. Always install servers into racks from the bottom up. Standard Chassis Installation Installing the Chassis into a Rack 1.
  • Page 23: Optional Quick Installation Method

    Chapter 2: Server Installation 6. Depress the locking tabs of both sides at the same time and push the chassis all the way into the rear of the rack. 7. If necessary for security purposes, use screws to secure the chassis handles to the front of the rack.
  • Page 24 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes 2-10...
  • Page 25: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview The front control panel provides LEDs and buttons for the system. These LEDs provide constant information on the system and on the overall health of system components. There are additional LEDs on each of the drive carriers. This chapter explains the meanings of the LED indicators and the appropriate responses that may need to be taken.
  • Page 26: Reset

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Reset Use the reset button to reboot the system. Power The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
  • Page 27: Nic1

    Chapter 3: System Interface NIC1 Indicates network activity on GLAN1 when fl ashing. NIC2 Indicates network activity on GLAN2 when fl ashing. Information LED This LED will be solid blue when the UID function has been activated. When this LED fl ashes red, it indicates a fan failure. When red continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl...
  • Page 28: Power Failure

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Power Failure When this LED fl ashes, it indicates a power failure in one of the power supplies. Drive Carrier LEDs Two LEDs are located on the front of each drive carrier. • Green: Each drive carrier has a green LED. When illuminated, this green LED (on the front of the drive carrier) indicates drive activity.
  • Page 29: About Standardized Warning Statements

    Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance.
  • Page 30 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 31 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 32: Installation Instructions

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 33: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 34: Power Disconnection Warning

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
  • Page 35 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 36: Equipment Installation

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi...
  • Page 37: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 38: Battery Handling

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻓﻘﻂ‬...
  • Page 39 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 40: Redundant Power Supplies

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 41: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 42: Comply With Local And National Electrical Codes

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬ 경고! 시스템이...
  • Page 43: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 44: Hot Swap Fan Warning

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 45 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 46: Power Cable And Ac Adapter

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi...
  • Page 47 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi...
  • Page 48 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes 4-20...
  • Page 49: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect cables and install add-on cards and describes all jumpers and connections. A layout and quick reference chart are included in this chapter for your reference. Always close the chassis when you have fi...
  • Page 50: Connecting Cables

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Connecting Cables Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been care- fully routed to prevent them from blocking the fl...
  • Page 51: I/O Ports

    Chapter 5: Advanced Serverboard Setup Figure 5-1. Control Panel Header Pins Ground x (Key) x (Key) Power On LED 3.3V HDD LED FP UID/3.3V Stby NIC1 LED (Link) NIC1 LED (Activity) NIC2 LED (Link) NIC2 LED (Activity) OH/Fan Fail/PWR Fail/UID LED Blue LED (UID Cathode) PWR Fail LED 3.3V...
  • Page 52: Installing The Processor And Heatsink

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Installing the Processor and Heatsink Warning: Avoid placing direct pressure to the top of the processor package. Always remove the power cord fi rst before adding, removing or changing any hardware com- ponents. Notes: • Always connect the power cord last and always remove it before adding, re- moving or changing any hardware components.
  • Page 53 Chapter 5: Advanced Serverboard Setup 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st' lever to open the load plate. Lift the load plate to open it completely. Gently push 4. Using your thumb and the index down to pop the load plate fi...
  • Page 54 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly, do not force it as it may damage the CPU. Instead, open the load plate again and double-check that the CPU has been inserted properly.
  • Page 55: Installing A Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup Installing a CPU Heatsink 1. Remove power from the system and unplug the AC power cord from the power supply. 2. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied.
  • Page 56: Memory Support

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Installing Memory Caution: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The X9DRG-HF+II/X9DRG-HTF+II supports up to 1 TB of ECC LRDIMMs, 512 GB of ECC RDIMMs or 128 GB of ECC/non-ECC UDIMMs in 16 DIMM slots (DDR3- 1866/1600/1333/1066/800 MHz).
  • Page 57: Processor/Dimm Population Confi Gurations

    Chapter 5: Advanced Serverboard Setup Processor/DIMM Population Confi gurations For memory to work properly, follow the tables below for memory installation. • For memory to operate properly, please install DIMMs in pairs (have an even number of DIMMs installed). • All channels in a system will run at the fastest common frequency.
  • Page 58: Expansion Cards

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual RDIMM Support POR DIMMs RDIMM Type DIMM Popu- (RDIMM = Regis- Ranks per DIMM Slots per lated POR Speeds (in MHz) tered DIMMs) (Any Combination) Channel per DDR Channel Reg. ECC DDR3 1066/1333/1600 SR, DR, or QR Reg.
  • Page 59: Serverboard Details

    Chapter 5: Advanced Serverboard Setup Serverboard Details Figure 5-4. X9DRG-HF+II/ X9DRG-HTF+II Layout USB/0/1 JWD1 JPG1 JLAN2 JLAN1 IPMI LAN CTRL BIOS Battery JBT1 JPME2 JSD1 JPLD1 X9DRG-HF+II Rev. 1.00 CPU1 CLOSE 1st Use Heatsink SNK-P0048PS OPEN 1st CPU2 CLOSE 1st Use Heatsink FANH SNK-P0047PS...
  • Page 60: X9Drg-Hf+Ii/ X9Drg-Htf+Ii Quick Reference

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual X9DRG-HF+II/ X9DRG-HTF+II Quick Reference Jumper Description Default Setting JBT1 Clear CMOS See Section 5-8 JBR1 ME Recovery Pins 2-3 (Normal) JPB1 BMC Enable/Disable Pins 1-2 (Enabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN1/LAN2 Enable/Disable Pins 1-2 (Enabled) JPME1 Manufacturer Mode...
  • Page 61 Chapter 5: Advanced Serverboard Setup I-SATA 0~5 SATA 3.0 (I-SATA 0/1) and SATA 2.0 Ports (I-SATA 2~5) S-SATA 0~3 SATA 2.0 Ports (S-SATA 0~3) PCI Slot 1/Slot 2 PCI-E 3.0 x16 Slots (Available when CPU1 is populated) PCI Slot 5 PCI-E 3.0 x8 in x16 Slot (Available when CPU1 is populated) PCI Slot 3/Slot 4 PCI-E 3.0 x16 Slots (Available when CPU2 is populated)
  • Page 62: Connector Defi Nitions

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Connector Defi nitions Power Connectors 12V 8-pin Power Connector Pin Defi nitions Three SMC-proprietary power connectors Pins Defi nition are located at JPW1, JPW2 and JPW9 to 1 through 3 +12V provide main power to the serverboard. 4 through 8 Ground Seven 12V, 8-pin power connectors, lo-...
  • Page 63 Chapter 5: Advanced Serverboard Setup Reset Connector Reset Button Pin Defi nitions (JF1) The reset connector is located on pins 3 Pin# Defi nition and 4 of JF1 and attaches to the reset Reset switch on the computer chassis. See the Ground table on the right for pin defi...
  • Page 64 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual HDD/FP UID Button The HDD/UID button connections are located on pins 13/14 of JF1. Attach a hard-drive LED cable to display HDD or HDD/UID LED SATA activity. This connection can also be Pin Defi nitions (JF1) used for the front panel UID (Unit Identi- Pin# Defi...
  • Page 65 Chapter 5: Advanced Serverboard Setup NMI Button NMI Header Pin Defi nitions The non-maskable interrupt header is lo- Pin# Defi nition cated at JNMI1. Refer to the table on the Control right for pin defi nitions. Ground Internal Buzzer Internal Buzzer Pin Defi...
  • Page 66 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual TPM/Port 80 Header Pin Defi nitions Pin# Defi nition Pin # Defi nition TPM Header/Port 80 LCLK A Trusted Platform Module/Port 80 header LFRAME# <(KEY)> is located at JTPM1 to provide TPM and LRESET# Port 80 support, which will enhance system LAD 3 LAD 2 performance and data security.
  • Page 67 Chapter 5: Advanced Serverboard Setup Unit Identifi er Switch A Unit Identifi er (UID) switch and two LED indicators are provided on the serverboard. UID LED (LE4) Status The rear UID LED (LE4) is located next Color/State OS Status to the rear UID switch. The front panel Blue: Windows OS Unit Identifi...
  • Page 68: Jumper Settings

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used Connector to choose between optional settings. Pins Jumpers create shorts between two pins to change the function of the con- nector.
  • Page 69 Chapter 5: Advanced Serverboard Setup LAN1/2 Enable/Disable LAN1/2 Enable/Disable Change the setting of jumper JPL1 to en- Jumper Settings able or disable the LAN1/LAN2 Ethernet Jumper Setting Defi nition ports on the serverboard. See the table on Pins 1-2 Enabled the right for jumper settings.
  • Page 70: Onboard Indicators

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual BMC Enable/Disable BMC Enable/Disable Jumper Settings Use jumper JPB1 to enable or disable the Both Jumpers Defi nition BMC (Baseboard Management Controller), Pins 1-2 Enabled which supports IPMI 2.0/KVM. See the Pins 2-3 Disabled table on the right for jumper settings. Onboard Indicators LAN1/2 Port LEDs The Ethernet ports have two LEDs.
  • Page 71: 5-10 Sata Ports

    Chapter 5: Advanced Serverboard Setup ME Recovery JBR1 is used for ME Firmware Recovery ME Recovery Select mode, which will limit system resources for Jumper Settings essential function use only without putting Jumper Setting Defi nition restrictions on power use. In the single Pins 1-2 Manufacture Mode operation mode, online upgrade will be...
  • Page 72: 5-11 Installing Software

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual 5-11 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 73 Chapter 5: Advanced Serverboard Setup SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
  • Page 74 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Figure 5-7. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
  • Page 75: 5-12 Onboard Battery

    Chapter 5: Advanced Serverboard Setup 5-12 Onboard Battery Care must be taken to assure that the chassis cover is in place when the system is operating to ensure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed. Figure 5-8.
  • Page 76 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes 5-28...
  • Page 77: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC218GHTS chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step.
  • Page 78: Control Panel

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Figure 6-1. Chassis: Front and Rear Views Control Panel Drive Bays 0-9 Low-Profi le PCI-E Slots (2) Standard Size PCI-E Slots (3) Note: the number of PCI slots available depend on the presence of GPUs in the server.
  • Page 79 Chapter 6: Advanced Chassis Setup Replacing a System Fan (Figure 6-2) 1. Remove the chassis cover. If necessary, do this with the power on in order to determine which fan has failed, then power-down the system and disconnect the chassis power cord. 2.
  • Page 80 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual 3. Lift the fan housing up and out of the chassis. 4. Disconnect the fan cable. 5. Examine the drawings below, then disassemble the fan housing by removing the front and rear fan guards (A). 6.
  • Page 81: Optional Fans

    Chapter 6: Advanced Chassis Setup Optional Fans Optional fans may be installed in the middle section of the chassis and to the outside rear of the chassis to provide additional cooling. Adding the Optional Mid-Section Fan These two optional fans are used to provide additional cooling for 1x GPU or 2x full-height, low-profi...
  • Page 82 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual 3. Install the fan bracket by securing it to the rear of the chassis with two screws as shown below. 4. Connect the fan cable to the Fan D header on the motherboard. 5. Remove the small cover over the cable access hole at the bottom right of the fan bracket.
  • Page 83: Installing The Air Shroud

    Chapter 6: Advanced Chassis Setup Installing the Air Shroud Air shrouds concentrate airfl ow to maximize fan effi ciency. The air shroud does not require screws for installation. Installing the Air Shroud 1. Lay the chassis on a fl at, stable surface and remove the chassis cover. 2.
  • Page 84: Drive Bay Installation/Removal

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Drive Bay Installation/Removal The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the drive bays. For this reason, even empty carriers without drives installed must remain in the chassis.
  • Page 85 Chapter 6: Advanced Chassis Setup Dummy Drive Hard Drive Carrier Figure 6-9. Removing a Dummy Drive from the Drive Carrier Installing a Hard Drive into a Drive Carrier 1. Remove the four screws securing the dummy drive to the hard drive carrier. 2.
  • Page 86: Expansion Card Setup

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Expansion Card Setup The system supports the following PCI-Express expansion cards and an expansion card bracket: • One low-profi le PCI-E 3.0 (x8) card (in x16 slot) • One full-height, full-length PCI-E 2.0 (x4) card (in x16 slot) Figure 6-11.
  • Page 87 Chapter 6: Advanced Chassis Setup Figure 6-12. Installing Expansion Cards into the Expansion Card Bracket Figure 6-13. Installing the Expansion Card Bracket into the Chassis 6-11...
  • Page 88: Low-Profi Le Expansion Card Setup

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Figure 6-14. Installing a Low-Profi le Expansion Card Low-Profi le Expansion Card Setup Four low-profi le PCI-E 2.0 (x8) expansion card slots are available for use with riser cards. The chassis has four low-profi le PCI slots available in order to accomodate a variety of riser card and add-on card combinations.
  • Page 89: Installing Graphics (Gpu) Cards

    Chapter 6: Advanced Chassis Setup Installing Graphics (GPU) Cards The chassis supports four GPU cards, which are mounted in brackets to fi t into the PCI-E 3.0 slots at the front of the chassis. NVIDIA Kepler K10/K20/K40 GPUs are supported. The GPU cards may be preinstalled, the procedure below is provided for when a GPU card needs to be replaced.
  • Page 90 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Figure 6-16. Installing GPU Cards into the Left and Right GPU Brackets Airfl ow Left Side GPU Bracket Right Side GPU Bracket and Cards and Cards Important Note for Kepler GPUs: note the airfl ow arrows on top of the GPU card. The card with the arrow pointing toward the Tesla logo should go on the left side of the chassis, and the card with the arrow pointing away from the Tesla logo should go on the right side of the chassis (when viewed from the front of the system).
  • Page 91: Power Supply

    Chapter 6: Advanced Chassis Setup Power Supply The system includes a dual 1600 Watt power supply, which is auto-switching capable. The power supply automatically senses and operates at a 100v to 240v input voltage. Note that different input voltages will result in different maximum power output levels.
  • Page 92 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes 6-16...
  • Page 93: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup utility for the X9DRG-HF+II/X9DRG- HTF+II. It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.
  • Page 94: Main Setup

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual How To Change the Confi guration Data The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Delete> at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted @http://www.supermicro.com/support/manuals/.
  • Page 95 Chapter 7: BIOS System Date/System Time Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values through the keyboard and press <Enter>. Press the <Tab> key to move between fi elds. The date must be entered in Day MM/DD/YY format.
  • Page 96: Advanced Setup Confi Gurations

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Advanced Setup Confi gurations Select the Advanced tab to access the following submenu items. Boot Features Quiet Boot This feature allows the user to select bootup screen display between POST mes- sages and the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages.
  • Page 97 Chapter 7: BIOS Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks.
  • Page 98 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual • CPU Stepping • Maximum CPU Speed • Minimum CPU Speed • Processor Cores • Intel HT (Hyper-Threading) Technology • Intel VT-x Technology • Intel SMX Technology • L1 Data Cache • L1 Code Cache •...
  • Page 99 Chapter 7: BIOS Active Processor Cores Set to Enabled to use a processor's second core and above. (Please refer to Intel's website for more information.) The options are All, 1, 2, 4 and 6. Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value. Enable this function to boot the legacy operating systems that cannot support processors with extended CPUID functions.
  • Page 100 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Intel® Virtualization Technology (Available when supported by the CPU) Select Enabled to support Intel Virtualization Technology, which will allow one platform to run multiple operating systems and applications in independent parti- tions, creating multiple "virtual" systems in one physical computer. The options are Enabled and Disabled.
  • Page 101 Chapter 7: BIOS CPU C6 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off.
  • Page 102 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Short Duration Power Limit This item displays the time period during which short duration power is main- tained. The default setting is 0. Chipset Confi guration North Bridge This feature allows the user to confi gure the settings for the Intel North Bridge. Integrated IO Confi...
  • Page 103 Chapter 7: BIOS IIO 1 PCIe Port Bifurcation Control This submenu confi gures the following IO PCIe Port Bifurcation Control settings for IIO 1 PCIe ports to determine how the available PCI-Express lanes to be distributed between the PCI-Exp. Root Ports. CPU1 Slot5 PCI-E 3.0 x8 Link Speed This feature allows the user to set the PCI-Exp bus speed for the slot specifi...
  • Page 104 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual QPI (Quick Path Interconnect) Link Speed Mode Use this feature to select data transfer speed for QPI Link connections. The options are Fast and Slow. QPI Link Frequency Select Use this feature to select the desired QPI frequency. The options are Auto, 6.4 GT/s, 7.2 GT/s, and 8.0 GT/s.
  • Page 105 Chapter 7: BIOS DRAM RAPL Mode RAPL (Running Average Power Limit) provides mechanisms to enforce power consumption limits on supported processors The options are DRAM RAPL MODE0 , DRAM RAPL MODE1, and Disabled. DDR Speed Use this feature to force a DDR3 memory module to run at a frequency other than what is specifi...
  • Page 106 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Thermal Throttling Throttling improves reliability and reduces power consumption in the processor via automatic voltage control during the processor idle state. The options are Disabled and CLTT (Closed Loop Thermal Throttling). South Bridge Confi guration This feature allows the user to confi...
  • Page 107 Chapter 7: BIOS SATA Confi guration When this submenu is selected, the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items. SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port as detected by the BIOS.
  • Page 108 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Port 0~5 Hot Plug Select Enabled to enable hot-plug support for the particular port. The options are Enabled and Disabled. SCU (Storage Control Unit) Confi guration Storage Controller Unit Select Enabled to enable PCH SCU storage devices. The options are Disabled and Enabled.
  • Page 109 Chapter 7: BIOS SERR# Generation Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus Signal Error Event. The options are Enabled and Disabled. Maximum Payload Select Auto to allow the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system performance.
  • Page 110 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual VGA Priority This feature allows the user to select the graphics adapter to be used as the primary boot device. The options are Onboard, and Offboard. Network Stack Select Enabled enable PXE (Preboot Execution Environment) or UEFI (Unifi ed Extensible Firmware Interface) for network stack support.
  • Page 111 Chapter 7: BIOS Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Terminal Type This feature allows the user to select the target terminal emulation type for Con- sole Redirection.
  • Page 112 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled. Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server.
  • Page 113 Chapter 7: BIOS Out-of-Band Management Port The feature selects a serial port used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote server. The options are COM1 and SOL. Terminal Type This feature allows the user to select the target terminal emulation type for Con- sole Redirection.
  • Page 114 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual NUMA (NON-Uniform Memory Access) This feature enables the Non-Uniform Memory Access ACPI support. The options are Enabled and Disabled. High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback, reducing the de- pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-...
  • Page 115 Chapter 7: BIOS Intel TXT (LT-SX) Confi guration Intel TXT (LT-SX) Hardware Support This feature indicates if the following hardware components support the Intel Trusted Execution Technology. CPU: TXT (Trusted Execution Technology) Feature Chipset: TXT (Trusted Execution Technology) Feature Intel TXT (LT-SX) Confi guration This feature displays the following TXT confi...
  • Page 116: Event Logs

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Event Logs Select the Event Logs tab to access the following submenu items.  Change SMBIOS Event Log Settings This feature allows the user to confi gure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot.
  • Page 117 Chapter 7: BIOS Erasing Settings Erase Event Log Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which is completed before a event logging is initialized upon system reboot. The options are No and Yes. When Log is Full Select Erase Immediately to immediately erase SMBIOS error event logs that ex- ceed the limit when the SMBIOS event log is full.
  • Page 118: Ipmi

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual IPMI Select the IPMI (Intelligent Platform Management Interface) tab to access the fol- lowing submenu items. IPMI Firmware Revision This item indicates the IPMI fi rmware revision used in your system. IPMI Status This item indicates the status of the IPMI fi rmware installed in your system. ...
  • Page 119 Chapter 7: BIOS When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately. Note: After making changes on a setting, be sure to reboot the system for the changes to take effect.
  • Page 120: Boot

    UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Station MAC Address This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit hexadecimal numbers. Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
  • Page 121: Security

    Chapter 7: BIOS  Delete Boot Option This feature allows the user to select a previously defi ned boot device to delete from the boot device list so that this device can no longer be used for system boot.  Network Device BBS Priorities This feature allows the user to specify which Network devices are boot devices.
  • Page 122 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 8 characters long. 7-30...
  • Page 123: Save & Exit

    Chapter 7: BIOS Save & Exit This submenu allows the user to confi gure the Save and Exit settings for the system. Discard Changes and Exit Select this option to exit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit, and press <Enter>.
  • Page 124 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Discard Changes Select this feature and press <Enter> to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previ- ous values, click Yes to load the values previous saved, or click No to keep the changes you've made so far.
  • Page 125 Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 126 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes...
  • Page 127 Appendix B: System Specifi cations Appendix B System Specifi cations Processors Two Intel Xeon E5-2600 series processors in LGA 2011 sockets Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C602 BIOS 128Mb SPI Flash EEPROM with AMI® BIOS Memory Capacity Sixteen DIMM sockets supporting up to 512 GB of registered ECC DDR3- 1600/1333/1066 MHz RDIMMs or 128 GB of ECC/non-ECC UDIMMs...
  • Page 128 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual 2027GR-TRH2/TRHT2: Six PCI-Express 3.0 x16 slots to support six double- width GPU cards. Additional slot supports one low-profi le PCI-Express 3.0 x8 cards (in x16 slot) Serverboard X9DRG-HF+II/X9DRG-HTF+II (proprietary ATX form factor) Dimensions: 19.7" x 9.2" (500.4 x 233.7 mm) Chassis SC218GHTS-R1K66BP (2U rackmount) Dimensions: (WxHxD) 17.2 x 3.5 x 30.5 in.
  • Page 129 Appendix B: System Specifi cations Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”...
  • Page 130 UPER ERVER 2027GR-TR2/TRT2/TRH2/TRHT2 User's Manual Notes...

Table of Contents