Troubleshooting
Fault
code No.
Designation
341
AL Open Load Cylinder
A1
342
AL Open Load Cylinder
A2
343
AL Open Load Cylinder
A3
344
AL Open Load Cylinder
A4
345
AL Open Load Cylinder
A5
346
AL Open Load Cylinder
A6
347
AL Open Load Cylinder
A7
348
AL Open Load Cylinder
A8
349
AL Open Load Cylinder
A9
350
AL Open Load Cylinder
A10
351
AL Open Load Cylinder
B1
352
AL Open Load Cylinder
B2
353
AL Open Load Cylinder
B3
354
AL Open Load Cylinder
B4
355
AL Open Load Cylinder
B5
356
AL Open Load Cylinder
B6
357
AL Open Load Cylinder
B7
358
AL Open Load Cylinder
B8
359
AL Open Load Cylinder
B9
360
AL Open Load Cylinder
B10
M015710/01E 07-02
Meaning
Alarm configuration; Disruption
fault in injector cabling to
cylinder. Result: Misfiring.
Task
1. Check solenoid
valve.
2.
Contact
Service.
87
Related
parameter No.
1.8004.540
1.8004.541
1.8004.542
1.8004.543
1.8004.544
1.8004.545
1.8004.546
1.8004.547
1.8004.548
1.8004.549
1.8004.550
1.8004.551
1.8004.552
1.8004.553
1.8004.554
1.8004.555
1.8004.556
1.8004.557
1.8004.558
1.8004.559
© MTU