Troubleshooting
Fault
code No.
Designation
270
SD Frequency Input
301
AL Timing Cylinder A1
302
AL Timing Cylinder A2
303
AL Timing Cylinder A3
304
AL Timing Cylinder A4
305
AL Timing Cylinder A5
306
AL Timing Cylinder A6
307
AL Timing Cylinder A7
308
AL Timing Cylinder A8
309
AL Timing Cylinder A9
310
AL Timing Cylinder A10
311
AL Timing Cylinder B1
312
AL Timing Cylinder B2
313
AL Timing Cylinder B3
314
AL Timing Cylinder B4
315
AL Timing Cylinder B5
316
AL Timing Cylinder B6
317
AL Timing Cylinder B7
318
AL Timing Cylinder B8
319
AL Timing Cylinder B9
320
AL Timing Cylinder B10
M015710/01E 07-02
Meaning
SD alarm configuration;
Frequency input faulty; short
circuit or wire break.
Alarm configuration;
Time-of-flight measuring
fault of injector: Time-of flight
measured value extremely
low or extremely high.
Task
1. Check cabling
2. Check
setpoint speed
transmitter.
3. Contact
Service.
Replace injector
concerned if the
fault message
appears frequently
(→ Page 109).
85
Related
parameter No.
2.8006.590
1.8004.500
1.8004.501
1.8004.502
1.8004.503
1.8004.504
1.8004.505
1.8004.506
1.8004.507
1.8004.508
1.8004.509
1.8004.510
1.8004.511
1.8004.512
1.8004.513
1.8004.514
1.8004.515
1.8004.516
1.8004.517
1.8004.518
1.8004.519
© MTU