Engine Coolant - Draining - MTU 12 V 4000 G23 Technical Documentation Manual

Table of Contents

Advertisement

142
6.14.3
Engine coolant – Draining
Preconditions
• Engine is stopped and starting disabled.
Coolant is hot and under pressure.
Risk of injury and scalding!
WARNING
Preparatory steps
1. Provide an appropriate container to drain the coolant into.
2. Switch off preheating unit.
Engine coolant – Draining
1. Turn breather valve of coolant expansion tank
counterclockwise until the first stop and allow
pressure to escape.
2. Continue to turn breather valve counterclockwise
and remove.
3. Draw off segregated corrosion inhibitor oil in
expansion tank through the filler neck.
4. Open drain cocks or drain plugs and drain coolant
at the following points:
• Preheating unit;
• Thermostat housing (arrow)
• U-bend (arrow)
• HT coolant pump elbow;
• Crankcase, left and right side.
5. Close all open drain points.
6. Place breather valve on filler neck and close.
M015710/01E 07-02
• Let the engine cool down.
• Wear protective clothing, gloves, and goggles / safety mask.
Task Description
© MTU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents