3. Consumable Item Replacement
• If there is no media stopper, secure the screw in the screw hole shown in the figure.
8
Close the maintenance covers.

Media Cutter Replacement

Replace cutters when blades are chipped or blunt.
• Avoid touching the cutter blade. Failure to do so may result in injury.
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the front cover.
• The carriage can be moved by hand. Move the carriage slowly to a position allowing easy
access while replacing.
4
Loosen the screws and open the carriage cover window.
28