2. Maintenance Methods
8
Fill the cap with maintenance liquid.
• Use a syringe to draw up some maintenance liquid and fill until it almost overflows from the cap.
9
Close the front cover, then press the [ENTER] key.
10
Set the exposure time, then press the [ENTER] key.
• Print nozzle washing starts. The elapsed time is displayed on the display.
• The leaving time can be set on firmware version 6.3 or later.
• Cleaning is performed automatically once print nozzle washing has ended.
• "Fill the Liquid. Exit Next [ENT]" appears on the display.
11
Open the front cover.
12
Fill the cap with maintenance liquid.
• Use a syringe to draw up some maintenance liquid and fill until it almost overflows from the cap.
13
Close the front cover, then press the [ENTER] key.
• Pump tube (ink discharge channel below the cap) washing starts.
• Do not turn off the main power supply. Turning off the main power supply will disable the
automatic maintenance function (including nozzle clogging prevention function and ink
discharge channel cleaning function). This will increase the risk of ejection failures (e.g., nozzle
clogging or deflection).