MIMAKI UJV100-160 Care And Maintenance page 23

Hide thumbs Also See for UJV100-160:
Table of Contents

Advertisement

5
Remove the cap absorber.
• Push up the two tabs at the front to remove the cap absorber.
• Avoid ink dripping when removing the cap absorber.
6
Clean the carriage base.
7
Mount a new cap absorber.
• Push the tabs on the cap absorber into the slits at the rear of the C slider, and clip in the tabs at
the front.
Claw
8
Once replacement is complete, move the wiper back to the rear by hand.
9
Close the front cover, then turn on the power.
• Check to confirm that the carriage returns to the station.
Cap absorber
Cap base
Cap absorber
23
3. Consumable Item Replacement
Push in to engage tabs.

Advertisement

Table of Contents
loading