r Lens control command
Command
Sub command
VXX
LNSI2
VXX
LNSI3
VXX
LNSI4
VXX
LNSI5
<REMOTE 2 IN> terminal
It is possible to control the projector remotely (by external contact) from a control panel located away from the projector where remote control
signals cannot reach.
Use the <REMOTE 2 IN> terminal on the connecting terminals of the projector to connect to the control panel.
Installation locations in meeting rooms, etc.
Pin assignments and signal names
D-Sub 9-pin
Outside view
(5)
(1)
(9)
(6)
Attention
f When controlling, make sure to short-circuit pins (1) and (9).
f When pins (1) and (9) are short-circuited, the following buttons on the control panel and the remote control are disabled. Commands for
RS-232C and network functions corresponding to these functions are also disabled.
g Power <v/b> button on the control panel or the power on <b> button, power standby <v> button, and <SHUTTER> button on the remote
control
f When pins (1) and (9) are short-circuited, and then any pins from (3) to (7) and the pin (1) are short-circuited, the following buttons on the
control panel and the remote control are disabled. Commands for RS-232C and network functions corresponding to these functions are also
disabled.
g Power <v/b> button on the control panel or the power on <b> button, power standby <v> button, <RGB1/2> button, <DVI-D> button,
<VIDEO> button, <HDMI> button, <DIGITAL LINK> button, <DisplayPort> button, and <SHUTTER> button on the remote control
Note
f For pin (2) to pin (8) settings, you can make changes if you set [REMOTE2 MODE] to [USER]. (x page 90)
Chapter 6 Appendix — Technical information
Details
Lens H shift
+00000=Fine adjustment 1+, +00001=Fine adjustment 1-,
Lens V shift
+00100=Fine adjustment 2+, +00101=Fine adjustment 2-,
Lens focus
+00200=Coarse adjustment+, +00201=Coarse adjustment-
Lens zoom
Pin No.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Remark
Remote control
Remote control/contact control
Standby
RGB1
RGB2
DVI-D
Remote control board in another location
Signal name
Open (H)
GND
POWER
OFF
RGB1
Other
RGB2
Other
VIDEO
Other
HDMI
Other
DVI-D
Other
SHUTTER
OFF
Controlled by remote
RST/SET
control
Contact control
Lit
Lamp
VIDEO
HDMI
Short (L)
GND
ON
RGB1
RGB2
VIDEO
HDMI
DVI-D
ON
Controlled by external
contact
ENGLISH - 141