Performer Fresnel Mini
Problem
Probable cause(s)
No power to the fixture
One or more
fixtures do not
function at all
Internal fuse blown
Fixtures reset
The controller is not connected
correctly, but all
5-pin XLR Out of the controller does
respond erratically
not match XLR In of the first fixture
or not at all to the
on the link (i.e. signal is reversed)
controller
Poor data quality
Bad data link connection
Fixtures reset
Data link not terminated with 120
correctly, but some
respond erratically
Ohm termination plug
or not at all to the
Incorrect addressing of the fixtures
controller
One of the fixtures is defective and
disturbs data transmission on the
link
5-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed)
Fixture is too hot
No light or LEDs
cuts out
LEDs damaged
intermittently
The power supply settings do not
match local AC voltage and
frequency
Ordercode: 33055
Remedy
●
Check if power is switched on and
cables are plugged in
●
Return the device to your Showtec
dealer
●
Connect controller
●
Install a phase reversing cable between
the controller and the first fixture on the
link
●
Check data quality. If much lower than
100 percent, the problem may be a
bad data link connection, poor quality
or broken cables, missing termination
plug, or a defective fixture disturbing
the link
●
Inspect connections and cables.
Correct poor connections. Repair or
replace damaged cables
●
Insert termination plug in output jack of
the last fixture on the link
●
Check address setting
●
Bypass one fixture at a time until normal
operation is regained: unplug both
connectors and connect them directly
together
●
Have the defective fixture serviced by a
qualified technician
●
Install a phase-reversing cable between
the fixtures or swap pin 2 and 3 in the
fixture, that behaves erratically
●
Allow the fixture to cool down
●
Make sure air vents are not blocked
●
Turn up the air conditioning
●
Disconnect fixture and return to your
dealer
●
Disconnect fixture. Check settings and
correct if necessary
14