Risk of acid burns
First aid.
Warning
Disposal
Do not throw batteries in the bin.
Safety instructions
DANGER
Risk of fire and explosion
Do not place tools or other objects on the battery.
Naked flames and smoking must be strictly avoided.
Ensure the room is well ventilated when charging batteries.
Only use batteries and chargers approved by Kärcher (original
spare parts).
WARNING
Environmental risk due to improper disposal of batteries
Ensure that defect or used batteries are disposed of safely (con-
tact a waste management company or Kärcher Service).
Procedures in the event of unintentional release of battery
When used normally, and when observing the instructions, lead-
acid batteries do not pose any risk.
However, keep in mind that lead-acid batteries contain sulphuric
acid which can cause serious chemical burns and corrosion.
1. If there is spillage or, if the battery is leaking, acid is escaping,
lay down a binding agent such as sand. Do not let it reach the
sewer system, soil or a body of water.
2. Neutralise the acid with lime/baking soda and dispose of it ac-
cording to local regulations.
3. Contact a waste management company to dispose of faulty
batteries.
4. Rinse out your eyes or rinse off your skin with copious
amounts of fresh water if acid splashes into your eyes or onto
your skin.
5. Then consult a doctor immediately.
6. Wash any contaminated clothing with water.
7. Change clothes.
Order numbers and dimensions of batteries and
Note
The KM 85/50 W Bp Pack and KM 85/50 W Bp Pack 2SB variants
are delivered with batteries and charger.
● Kärcher order numbers for recommended batteries and
chargers
Battery set
Order no. *
Maintenance-
free
2 x 12 V /
2.815-137.0 2.64
115 Ah
* The order no. of the battery set contains 2 batteries
** Minimum volume of battery charging room
*** Minimum airflow between battery charging room and environ-
ment
22
acid
chargers
Volume
Airflow
3
3
m
**
m
/h ***
1.06
Charger
24 V / 12 A
● When using other batteries
Maximum dimensions per battery *
L x W x H
* 2 batteries are required
Installing / connecting batteries
ATTENTION
Risk of damage as a result of incorrect polarity
Make sure you connect the cables to the correct terminals.
Figure: Installation and connection of the batteries
Batteries
1
Negative cable to the battery connector
2
Positive cable to the battery connector
3
Connection cable
4
Spacers (2x)
5
1. Switch off the device and remove the key from the key-operat-
ed switch.
2. Open or remove the device cover.
3. Place both batteries in the mount.
4. Insert both spacers.
5. Connect the connection cables as shown.
6. Connect the negative and positive cables to the battery con-
nector as shown.
DANGER
Risk of fatal injury from electric shock
Only operate the charger from an appropriate power supply with
sufficient fuse protection.
Only use the charger in dry rooms with sufficient ventilation.
ATTENTION
Risk of damage due to deep discharge
The device has deep discharge protection, i.e. when the permit-
ted minimum capacity level is reached, you have to drive the de-
vice directly to the charging station and avoid slopes.
ATTENTION
Risk of damage caused by charger
Do not connect the charger to the device controller plug connec-
tor.
Note
Adhere to the safety instructions for charging batteries.
For further information on charging, please read the operating in-
structions for the charger and act accordingly.
English
Order no.
Required quantity
6.654-329.0
1
362 x 174 x 290 mm
Charging batteries

Advertisement