Simer 4185 Owner's Manual page 5

Submersible sump pumps

Advertisement

Available languages

Available languages

Operation
1. The shaft seal depends on water for
lubrication. Do not operate the pump unless
it is submerged in water; running it dry may
damage the seal.
2. If the pump overheats, an automatic-reset
thermal protector cuts off the power and stops
the motor before it can be damaged. The
motor will automatically restart when it cools.
If the protector trips repeatedly, unplug the
pump, remove it from the sump, and check
Performance
Model
4185/P
5100
4186
4188
5460
4190
5880
Electrical and Switch Specifications
Model
HP
4185/P
1/2
4186
4188
3/4
4190
1
Figure 7 – LIFT: The vertical distance the pump
actually lifts water. The higher the lift, the lower
the flow.
GPH at total feet of lift
5 ft.
10 ft.
Capacity Gallons/Hour
4140
4500
4980
Motor Full Load
Amps
7.3
7.5
7.9
For parts or assistance, call Simer Customer Service at 800-468-7867
it for the cause of the difficulty. Low voltage,
long extension cords, clogged impeller, very
low lift, a plugged or frozen discharge pipe,
etc., can all cause cycling and overheating.
3. This pump will not remove all the water in the
sump (see off switch setting, below). If you are
running the pump manually and water stops
coming out of the discharge, the pump has
probably run dry. Shut it off immediately and
check the water level.
15 ft.
20 ft.
2940
1380
3420
2100
4020
2880
Individual Branch
Circuit Req. (Amps)
15
NOTICE The friction caused by water running
through the pipe will also, on longer pipe runs,
reduce the flow. Pipe smaller than the pump
discharge also reduces flow.
25 ft.
No flow at
height shown
below
-
23 ft.
420
26 ft.
1500
29 ft.
*Switch Setting in Inches
Water Level For:
On
13-1/2"
7-1/2"
5
Off
4-1/2"
3"

Advertisement

loading

This manual is also suitable for:

4185p418641884190