LUNA2000-(5-30)-NHS0
User Manual
----End
6.3.2 Installing DC Input Power Cables
Connect DC input power cables to the inverter
Insert the positive and negative battery connectors (Staubli) into the
corresponding DC input terminals (BAT+ and BAT–).
Step 1 Assemble DC connectors.
Figure 6-11 Assembling DC connectors
● For battery terminals, use the delivered Staubli MC4 positive and negative
● You are advised to use the PV-CZM-19100 crimping pliers or other crimping
Issue 11 (2023-04-15)
NO TE
It is recommended that silica gel or paint be used around the ground terminal after the PE
cable is connected.
NO TE
The DC input terminals (BAT+ and BAT–) on the left and right sides of the battery are the
same.
CA UTION
metal terminals and DC connectors. Using incompatible positive and negative
metal terminals and DC connectors may burn the cables or damage the
module. The resulting device damage will not be covered under warranty.
pliers with the same specifications.
Copyright © Huawei Technologies Co., Ltd.