LUNA2000-(5-30)-NHS0
User Manual
Table 8-3 Impact of force SOH calibration
ESS Working
Mode
TOU
Max. self-
consumption
Fully fed to
grid
Issue 11 (2023-04-15)
Current Charge/
Discharge Status
Charging
Discharging
The PV power is
greater than the
load power and
battery charge
power, and the
surplus PV power is
fed to the grid.
The PV power is
greater than the
load power, and
batteries are
charging.
The PV power is
less than the load
power, and
batteries are
discharging.
The PV power is
greater than the
power limit at the
grid-connection
point, and batteries
are charging.
Copyright © Huawei Technologies Co., Ltd.
SOH Calibration's
Impact on
Charging
The ESS working
mode is not
affected. Batteries
are charging at the
maximum power.
Batteries stop
discharging and are
charging at the
maximum power.
The ESS working
mode is not
affected. Batteries
are charging at the
maximum power.
Batteries are
charging at the
maximum power.
Power from the grid
may be supplied to
loads.
Batteries stop
discharging and are
charging at the
maximum power.
More power from
the grid is supplied
to loads.
The battery is
charging at the
maximum power,
and the feed-in
power decreases.
8 System Maintenance
SOH
Calibration's
Impact on
Discharging
Batteries are
discharging at the
current load
power (the
discharged
battery energy
cannot be fed to
the grid).
1. When the
battery discharge
power is greater
than the load
power, the battery
discharges and
the surplus PV
power cannot be
fed to the grid.
The inverter
power is limited,
affecting the
energy yield.
2. If the battery
discharge power
is less than the
load power, the
PV power is
supplied to loads
at the same time.
Batteries are
discharging at the
maximum power,
and the total
power of PV and
batteries is less
than the power
limit at the grid-
connection point.
In the daytime,
the PV power fully
charges the
batteries. At
night, the
94