14. MALFUNCTION CODE
14.4.3
0018: Developing motor malfunction
Developing motor (M1)
Step
1
Check the connector between M1-PRCB
PJ5 for proper connection and correct as
necessary.
2
Check the M1 connector for proper drive
coupling and correct as necessary.
3
M1 operation check
4
Change M1.
5
Change PRCB.
14.4.4
0045: MFP board cooling fan motor malfunction
MFP board cooling fan motor (FM12)
Step
1
Check the connector between FM12-relay
CN64-PRCB PJ14 for proper connection
and correct as necessary.
2
Check the fan for possible overload and
correct as necessary.
3
FM12 operation check
4
Change FM12.
5
Change PRCB.
208
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.1 Jun. 2010
Print control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ5-10 to 13
-
-
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ14-7 (REM)
PRCB PJ14-9 (LOCK)
-
-
Location (electri-
cal component)
-
-
B-15
-
-
Location (electri-
cal component)
-
-
H-15
-
-