Electromagnetic wave radiation.
•
Common impedance (including the grounding system) coupling.
•
To prevent EMI, perform the following tasks:
If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE) to
•
filter interference from the power grid.
•
Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices.
Use electromagnetic shielding, for example, shielded interface cables, when necessary.
•
Laser safety
WARNING!
Do not stare into any fiber port when the switch has power. The laser light emitted from the optical fiber
might hurt your eyes.
The switch is a Class 1 laser device.
Installation tools
No installation tools are provided with the switch. Prepare the following tools yourself:
Phillips screwdriver.
•
•
ESD wrist strap.
Marker.
•
Installation accessories
Table 4 Installation accessories
Product code
5066-0850
5190-0719
Description
1 U mounting bracket kit
(including one pair of mounting
brackets and eight M4
countersunk screws)
Mounting brackets for the HP
5930-2Slot+2QSFP+/HP
5930-2Slot+2QSFP+ TAA
Quantity
1 kit
1 kit
4
Applicable models
•
HP 5930-32 QSFP+
•
HP 5930-32 QSFP+ TAA
•
HP 5930-2Slot+2QSFP+
•
HP 5930-2Slot+2QSFP+
TAA